background image

Laboratory Shaker
PN 4821, 115 Volt
PN 4822, 230 Volt 

Description

• Easily detachable arms equipped with 8 cork-lined clamps.
• Process up to 8 Envirochek

®

sampling capsules at one time.

• Programmable digital speed and timer.

© 2008, Pall Corporation, 07/08

PN 87333C

Pall Life Sciences

600 South Wagner Road
Ann Arbor, MI 48103-9019 USA

800.521.1520

USA and Canada

(+)800.PALL.LIFE

Outside USA and Canada

734.665.0651

phone

734.913.6114

fax

Visit us on the Web at www.pall.com/lab  

E-mail us at [email protected]

Australia,

Cheltenham, VIC, 03 9584 8100

Austria,

Wien, 00 1 49 192 0

Canada,

Ontario, 905-542-0330

Canada,

Québec, 514-332-7255

China,

P.R., Beijing, 86-10-6780 2288

France,

St. Germain-en-Laye, 01 30 61 32 32

Germany,

Dreieich, 06103-307 333

India,

Mumbai, 91 (0) 22 67995555

Italy,

Buccinasco, +3902488870.1

Japan,

Tokyo, 03-6901-5800

Korea,

Seoul, 82-2-560-8711

Malaysia,

Selangor, +60 3 5569 4892

Poland,

Warszawa, 22 510 2100

Russia,

Moscow, 5 01 787 76 14

Singapore,

65 6 389-6500

South Africa, 

Johannesburg, +27-11-2662300

Spain,

Madrid, 91-657-9876

Sweden,

Lund, (0)46 158400

Switzerland,

Basel, 061-638 39 00

Taiwan,

Taipei, 886 2 2545 5991

Thailand,

Bangkok, 66 2937 1055

United Kingdom,

Farlington, 02392 302600

Pall,

, and Envirochek are trademarks of Pall

Corporation. ® indicates a registered trademark in the USA.

1240_87333C.qxd:1240_87333C.qxd  7/23/08  5:31 PM  Page 1

Содержание 4821

Страница 1: ...192 0 Canada Ontario 905 542 0330 Canada Québec 514 332 7255 China P R Beijing 86 10 6780 2288 France St Germain en Laye 01 30 61 32 32 Germany Dreieich 06103 307 333 India Mumbai 91 0 22 67995555 Italy Buccinasco 3902488870 1 Japan Tokyo 03 6901 5800 Korea Seoul 82 2 560 8711 Malaysia Selangor 60 3 5569 4892 Poland Warszawa 22 510 2100 Russia Moscow 5 01 787 76 14 Singapore 65 6 389 6500 South Af...

Страница 2: ...plosive mixtures Packing List The standard equipment consists of the following components Piece Qty Laboratory Shaker 115 or 230 Volt 1 Arms 2 Clamps 8 Power Cord 1 Product Information Insert 1 Allen Wrench 3 mm 1 1 Table of Contents Section Page General Information 1 Packing List 1 Specifications 2 Installation 2 Instructions for Use 3 Maintenance 8 Replacement Parts 8 Warning 8 Note The procedur...

Страница 3: ... Hz or 230 V 50 60 Hz on the characteristics plate Part Number 4821 4822 Height 35 cm 13 8 in 35 cm 13 8 in Length 77 cm 30 3 in 77 cm 30 3 in Width 27 cm 10 6 in 27 cm 10 6 in Maximum capacity 4 kg 8 8 lb 4 kg 8 8 lb Oscillations min 100 750 rpm 100 920 rpm Power consumption 80 w 80 w Weight 11 kg 24 2 lb 11 kg 24 2 lb Voltage 115 V 230 V Installation Laboratory Shaker Place the apparatus on a le...

Страница 4: ...instrument Follow steps outlined below for Continuous Operation or Timed Operation Continuous Operation Example To run shaker in continuous non timed operation the timer must be set to 000 minutes If for example the desired shaking speed is 200 undulations cycles per minute U min for an undefined interval follow the steps outlined below 1 Press the Speed Selector button The Speed Mode Lamp will li...

Страница 5: ...Use Start Stop button to end a timed program or to stop shaking in continuous mode Timed Operation Example If the desired shaking speed is 450 undulations cycles per minute U min for an interval of 60 minutes follow the steps outlined below 1 Press the Speed Selector button to access the speed mode The Speed Mode Lamp will light and the display will read 000 2 Press and hold the Program button to ...

Страница 6: ...ichiarazione di garanzia pubblicata nel nostro più recente catalogo 9 8 Maintenance Before removing the casing always be sure the shaker is unplugged The manipulation of the internal electronic circuits of the apparatus by unauthorized personnel can cause irreparable damage to the apparatus Cleaning Cleaning of plastic alcohol with cotton cloth Painted metal case damp cloth and mild soap Replaceme...

Отзывы: