SBI521 Service Manual
23
3.4 Navigating the Weigh Mode
3.4.1 Change the Working Mode
Press the
[FUNC]
key for 3 seconds. Use the
[FUNC]
key to choose and confirm entry
into weighing mode, counting mode or percentage working mode. The count and/or
percentage mode must be set to yes in the FUNC menu within the setup mode.
Otherwise the indicator will only show the weighing mode. Refer to page
for details.
3.4.2 Enter or Exit the HOLD Mode
Press the
[HOLD]
key.
3.4.3 Zero
When the weight is stable and within the zero range, press the
[ZERO]
key to set a new
zero point. Refer to
for zero limitations.
3.4.4 Tare
When the gross weight is larger than zero and the scale is stable, press the
[TARE]
key. The indicator will show a net weight of zero and the NET annunciator will be
illuminated. Refer to
3.4.5 Preset Tare Weight
Enter a preset tare weight by pressing the
[PRESET]
key for more than 3 seconds.
Pr.Tare
will be displayed and the TARE annunciator flashes. Use the up and down
arrow keys to input the desired tare weight and the right arrow key to move to the next
digit. The value entered must be larger than zero and there is no limitation to preset
tare weight. After the tare weight is entered the NET annunciator will illuminate. Refer
to
for tare limitations.
Note: This indicator can only save one tare weight. The new tare weight will
automatically replace the old one.
3.4.6 Clear Tare Weight
Remove any weight on platform and wait until the scale is stable. Press the
[TARE]
key.