3.5.1 Enter Count Mode
1.
To enter counting mode press the
[FUNC]
key for more than 3 seconds.
WEIGH
will be displayed.
2.
Use the
[N/G]
or
[PRINT]
key to select COUNT.
3.
Press
[TARE]
to confirm the parts counting mode. The pcs annunciator will be
illuminated.
3a.
In counting mode, the function of
[ZERO]
,
[TARE]
,
[PRINT]
,
[HOLD]
,
[TARE]
,
[N/G]
,
[SETUP]
,
[ON/OFF]
keys are available.
3.5.2 Obtain Piece Weight
There are two ways to obtain the piece weight:
Input piece weight directly
1.
Press the
[UNIT]
key.
2.
When
InP.PWt
is displayed, press the
[TARE]
key to enter into the piece
weight mode.
3.
When
UNIT.KG
is shown, use the
[PRINT]
or
[N/G]
key to select the unit of
piece weight.
4.
Use the
[TARE]
key to confirm and go to piece weigh entry.
5.
Press the
[ZERO]
key to exit the piece weight mode and back to counting
mode.
6.
When last stored piece weight is shown, use
[PRINT]
,
[N/G]
,
[UNIT]
key to
input new piece weight.
7.
Press the
[SETUP]
key more than 3 seconds to input decimal point.
8.
Press the
[TARE]
key to confirm the entry and save it.
8a.
If the input piece weight is less than 0.5d, the indicator will display
PWt.Er
and go back to counting mode.
Sample a Known Quantity
1.
Press the
[UNIT]
key.
2.
When
InP.PWt
is shown, use the
[PRINT]
or
[N/G]
key to select SPL.PWT.
3.
Press the
[TARE]
key to weigh samples (which quantity is known) weight,
calculate piece weight.
4.
When
SPL.Lo
is shown, remove the sample on scale and press the
[TARE]
key to confirm.
5.
When
SPL.Hi
is shown, put samples (its quantity is known) onto the scale,
Press the
[TARE]
key to confirm reading weight.
6.
After
INP.PCS
is displayed,
000000
will be shown. Use the
[PRINT]
,
[N/G]
,
[UNIT]
key to input the quantity of samples.
7.
Press the
[TARE]
key to confirm.