![AGRI TRONIX Brecknell SBI-521 Series Скачать руководство пользователя страница 53](http://html1.mh-extra.com/html/agri-tronix/brecknell-sbi-521-series/brecknell-sbi-521-series_service-manual_2869497053.webp)
SBI521 Service Manual
51
NOTE: If AD.FROM = COM2, COM2 and OUT2 will be disabled.
OTHER
NLD.RNG
1-255
10
1-255=the range of weight is 1-
255d. When current weight is
less than this value, the scale
can be regarded as empty, or the
load on scale is removed.
It must be bigger than
(CONFI.MOTION).
CMD.SRC
NONE
COM.1
Source of the executed
command selection
(1)NONE=no any command will
be executed
COM.1
(2)COM.1= command from
COM1 will be executed
COM.2
(3)COM.2= command from
COM2 will be executed
COM1-2
(4)COM.1.2= command from
COM1 or COM2 will be executed
A.OFF.T
0-255
0
Auto off time
0=not auto power off
1-255=auto power off after 1-255
minutes. In this period, no
operation or no weight change
A.OFF.MD
OFF
OFF
Auto off mode
(1)OFF=turn off indicator
DSP.TIM
(2)DSP.TIM= display time
DSP.DAT
(3)DSP.DAT=display date
AC.TIME
(4)AC.TIME=turn off when only
battery is used. Display time
when AC adaptor is used
AC.DATE
(5)AC.DATE=turn off when only
battery is used. Display date
when AC adaptor is used
LCD.BLT
0-255
30
LCD backlight set
(1)0=always off
(1)1=always on
(2)2=press down ZERO+UNIT
together more than 3s to turn on
or turn off
(3)3-255=auto on when key
operation or weight changing.
Auto off after 3-255s elapsed.
*Only available on LCD version
LED.BRT BRT1-2-
3-4-5
BRT3
LED brightness level set
BRT1-BRT2-BRT3=low - high
*Only available on LED version
SCAL.ID 000000-
999999
123456
Scale ID number: 000000-
999999
USER
SubMenu1
SubMenu2
Option
Default
Parameter Description
Comment