![AGRI TRONIX Brecknell SBI-521 Series Скачать руководство пользователя страница 66](http://html1.mh-extra.com/html/agri-tronix/brecknell-sbi-521-series/brecknell-sbi-521-series_service-manual_2869497066.webp)
64
SBI521 Service Manual
Counting Mode:
Percent weighing mode:
6.5.3 CONFIG-AD.FROM=COM2
When CONFIG-AD.FROM is set to COM2, the original raw counts of weight are coming
from COM2. The raw counts from A/D chip on the local PCB are ignored.
NOTE:
(1) In legal trade application, CONFIG-AD.FROM=COM2 may be not allowed.
Please contact with your local legal metrology organization!
(2) In this application, Baud rate and byte format of COM2 is fixed to 9600bps and
8N1.
SCALE ID:
123456
GROSS:
1234.55kg
TARE:
12.15kg
NET:
1222.40kg
QUANTITY:
24448pcs
PIECE WT:
0.05kg
ACC. N:
10
TOTAL:
23456pcs
DATE:
2011-06-12
TIME:
12:34:56
A/D CODE:
1234345
VOLTAGE:
6.7V
STATUS:
bpq2
SCALE ID:
123456
GROSS:
12345lb
TARE:
10lb
NET:
12335lb
PERCENTAGE:
91.4%
1% REF. WT:
135lb
ACC. N:
3
TOTAL:
271.6%
DATE:
2011-06-12
TIME:
12:34:56
A/D CODE:
1231234
VOLTAGE:
6.7V
STATUS:
bpq2