![AGRI TRONIX Brecknell SBI-521 Series Скачать руководство пользователя страница 30](http://html1.mh-extra.com/html/agri-tronix/brecknell-sbi-521-series/brecknell-sbi-521-series_service-manual_2869497030.webp)
28
SBI521 Service Manual
7a.
If the calculated piece weight is less than 0.5d, the indicator will display
PWt.Er
and go back to counting mode. Otherwise, after the reasonable piece
weight has been captured, the scale will go back to counting mode. The piece
weight will be saved and used again.
3.5.3 Check Counts (counts compare) in Counting mode:
To make counts compare function be available, CONFIG-FUNC-COMPAR item should
set to YES, and high and low limitation of pieces should be set correctly according to
following steps:
1.
In counting mode, press down the
[DATA]
key more than 3 seconds to enter the
high and low compare data.
2.
When in HIGH mode,
000000
will be displayed. Use the
[PRINT]
,
[N/G]
,
[UNIT]
key to input high quantity number.
3.
Press the
[TARE]
key to confirm the entry. The Hi annunciator will be shown
on the display.
4.
When in LOW mode,
000000
will be displayed. Use the
[PRINT]
,
[N/G]
,
[UNIT]
key to input the low quantity number.
5.
Press the
[TARE]
key to confirm the entry. The Lo annunciator will be shown
on the display.
5a.
After a reasonable limitation is set and compare is active, one of annunciators
HI, OK, LO will be lit and the beeper will sound according to its setting in
USER-BEEP.
3.6 Percent Weigh Mode
In this mode the scale will calculate the weight on the scale and display its percentage
after the unit-percentage-weight is obtained. NOTE: If 100% display format is set to
100%, 100.0% or 100.00% in CONFIG-FUNC-PERCEN menu item, then, the unit-
percentage-weight is the weight of 1%, 0.1% or 0.01%.
To make percent weighing function be available, CONFIG-FUNC-PERCEN menu item
shouldn't be set to NONE.
3.6.1 Enter Percent Weighing Mode
1.
From the percent weighing mode, normal weighing or counting mode, press the
[FUNC]
key for more than 3 seconds.
WEIGH/COUNT
will be shown.
2.
Use the
[PRINT]
or
[N/G]
key to select PERCEN.
3.
Press the
[TARE]
key to confirm and go to percent weighing mode. The last
unit-percentage-weight will be used.
NOTE: If the High number value is 0 or is equal or less than low number, the
comparison will be disabled.