16
AGM Global Vision
RESTORE DEFAULT SETTING
Press the joystick Up/Down to Restore Default Setting, there will be no further
indication. The following settings will be restored to their original values before
changes made by user:
- Zoom
- Image Brightness
- Contrast
- Sharpness
- OLED Brightness
ALIGNMENT
All Anaconda-Micro are adjusted on the laboratory test equipment with ac-
curacy from 0.1 mrad to 0.3 mrad. The final accuracy depends on customer
riflescope, parallax of used rifle scope and shooting distance. Anaconda-Micro
is preset on 500 m distance.
Customer who would like to use device on the shorter distance could recognize
deviation and eliminate it by software correction.
The manufacturing process of the Anaconda-Micro ensures the shooting preci-
sion tolerance within 3 to 7 cm at 100 m. To achieve better result accuracy, use
Alignment Correction in main menu (See part 2.3.7 for more detailed).
2.3 OPERATING
2.3.1 TURNING THE DEVICE ON
Open the objective lens cover.
NOTE
The objective lens cover protects the scope from inadvertent exposure to extremely
high levels of radiant flux. Never leave the scope without confirming that the objective
lens is covered.
To turn the unit on push and hold the operation joystick.
2.3.2 FOCUSING
Anaconda-Micro
has the ability to focus over either long or short-range distances.
Rotate the front lens to focus it until the image becomes clear and sharp.