27
Setting the Interfaces - SDH Operation
Using Smart Test
Using Smart Test
Smart Setup
The Smart Setup feature simplifies instrument operation by:
•
Allowing the instrument to auto-configure on the incoming signal. It will attempt to
identify signal structure, and detect mixed payload signal structures and alarms.
The OmniBER 720 automatically displays all of the J1 trace identifiers. Once the
received signal has been identified you can select a channel of interest and explore
further into the payload.
Smart Tests
Allows you to quickly access the most commonly used instrument features such as:
•
Signal quality
•
Functional tests
•
Settings (stored, logging, Tx/Rx coupling and trigger output enable)
HOW TO:
1
Connect the OmniBER 720 to the network.
2
Press
.
3
With Smartsetup highlighted, press
to auto-discov
er
information about the
receive signal.
Or press
to exit Smart Tests.
SMART TEST
START
CANCEL
SONET_Usr.bk Page 27 Wednesday, December 13, 2000 11:11 AM