![Agilent Technologies N8900 series Скачать руководство пользователя страница 92](http://html1.mh-extra.com/html/agilent-technologies/n8900-series/n8900-series_operating-manual_2868446092.webp)
STATus Commands
*OPC?
Returns a 1 to the output buffer when all pending operations complete. The response is delayed until all pending oper-
ations complete.
Parameter
Typical Return
(none)
1
Return a 1 when commands complete: *OPC?
l
The purpose of this command is to synchronize your application with the instrument.
l
Other commands cannot be executed until this command completes.
*SRE <
value
>
*SRE?
Service Request Enable Command and Query
. Sets the value of the Service Request Enable register. This determines
which bits from the
Status Byte Register
are summed to set the Master Status Summary (MSS) bit and the Request for
Service (RQS) summary bit. A 1 in any Service Request Enable register bit position enables the corresponding Status
Byte register bit. All such enabled bits are then logically OR-ed to cause the MSS bit of the Status Byte register to be set.
Refer to
Status Tutorial
for more information.
The query reads the enable register and returns a decimal value which corresponds to the binary-weighted sum of all
bits set in the register.
Parameter
Typical Return
A decimal value that corresponds to the binary-
weighted sum of the bits in the register.
<bit value>
Enable bit 3 and 4 in the enable register: *SRE 24
l
When a serial poll is conducted in response to SRQ, the RQS bit is cleared, but the MSS bit is not.
l
When *SRE is cleared (by programming it with 0), the power supply cannot generate an SRQ to the controller.
*STB?
Status Byte Query
. Reads the
Status Byte Register
, which contains the status summary bits and the Output Queue
MAV bit. The Status Byte is a read-only register and the bits are not cleared when it is read. Refer to
Status Tutorial
for
more information.
Parameter
Typical Return
(none)
<bit value>
Read status byte: *STB?
Agilent N8900 Series Operating and Service Guide
91
Содержание N8900 series
Страница 1: ...Agilent N8900 Series Autoranging System DC Power Supply Operating and Service Guide...
Страница 36: ...Multiple Unit Connections Agilent N8900 Series Operating and Service Guide 35...
Страница 104: ...Status Tutorial Status Diagram Agilent N8900 Series Operating and Service Guide 103...
Страница 117: ...Service and Maintenance Service and Maintenance Pending 116 Agilent N8900 Series Operating and Service Guide...
Страница 118: ...Verification and Calibration Verification and Calibration Pending Agilent N8900 Series Operating and Service Guide 117...
Страница 119: ......