JITTer Subsystem(N4963A 101)
The jitter subsystem requires option N4963A-101.
The jitter subsystem provides the jitter programming capabilities for the
N4963A.
Command
:JITTer:SOURce { OFF | INTernal | EXTernal }
Description
Set the jitter of the N4963A. It is used to either turn the jitter off; or to set the
jitter source to the internal source or to the external signal provided to the
Jitter-In rear panel connector.
Command
:JITTer:SOURce?
Description
Query the jitter state of the N4963A. Returns values OFF, INT, or EXT.
Command
:JITTer:BAND { LOw | HIgh }
Description
Set the jitter path of the N4963A when using external jitter inputs. Low band
signals are digitized and scaled by the ExtUI=[1|2|4|8|16|32] parameter
which determines the maximum UI available with a full scale input signal. High
band signals pass thru analog signal processing blocks, are limited to a
reduced max UI value and do not receive any additional signal scaling.