Installing the Agilent N4916B

6

Assign a VISA Alias Name to the N4916B

If the 

Agilent Connection Expert 

does not pop up automatically, 
click the 

Agilent IO Control

 icon 

in the Windows task bar and 
start it from the menu.

1

In the 

Instrument I/O

 panel, 

click 

.

” is the default 

alias name.

UsbInstrument1

UsbInstrument1

2

Click 

Change Properties

 and change the

alias name to

 DATA_OUT or AUXDATA_OUT 

depending on the channel (Data Out and 
Aux Data Out) used.
This is the alias used by the software.

3

After clicking OK, 
the 

Agilent Connection Expert

 

shows a window like the following:

4

In this example, we use the 

Agilent Connection Expert

If your N4903B uses revision 

 of the 

Agilent IO Libraries Suite, you can run 

IO Config

 

for the same purpose.

IO-Lib 15.5

A VISA alias name is required by the software to
access the N4916B. 

The alias name 

DATA_OUT or AUXDATA_OUT

  

is mandatory. You should not use any other 
alias name.

Содержание N4916B

Страница 1: ...nline Help of your High Performance Serial BERT N4903B For more information visit The Help also offers printable versions of the User Guide and the Programming Guide www agilent com find jbert You onl...

Страница 2: ...I pollution degree 2 environment It is designed to operate within a temperature range of 5 40 C 40 105 F at a maximum relative humidity of 95 and at altitudes of up to 2000 meters Refer to the specifi...

Страница 3: ...the installation media All data and clock input and output connectors of the PG that are not used in your test setup must be terminated with 50 Ohm The instrument can operate from any single phase AC...

Страница 4: ...ct the Agilent IO Control icon in the Windows task bar 5 If you see this icon the revision of the Agilent IO Libraries Suite is 15 5 or later You may wish to connect a keyboard and mouse to your Seria...

Страница 5: ...he rear USB ports of your N4903B 3 When you connect the N4916B for the first time the Windows Found New Hardware Wizard appears and asks whether it should connect to Windows Update Answer No 4 Click N...

Страница 6: ...e alias name to DATA_OUT or AUXDATA_OUT depending on the channel Data Out and Aux Data Out used This is the alias used by the software 3 After clicking OK the Agilent Connection Expert shows a window...

Страница 7: ...these functions 5 Enabling Clock Multiplier Select the Clock Multiplier function to open the Clock Multiplier Connection dialog 7 If you select the Clock Multiplier function a new menu entry is added...

Страница 8: ...For details see the Help and the User Guide Choose a suitable pattern e g PRBS and start the pattern generator 9 After some adjustments of the scope you will see a display like the following 10 In ca...

Страница 9: ...of problems please refer to the section Problems with the N4916B of the Help and the User Guide of your N4903B Preset the instrument state 1 Preset the instrument state 1 Enable Clock Multiplier from...