Safety Summary

Services and Support

Any adjustment, maintenance, or repair of this 

product must be performed by qualified personnel. 

Contact your customer engineer through your local 

Agilent Technologies Service Center. You can find 

a list of local service representatives on the Web at:

http://www.agilent.com/find/techsupport

Operating personnel must not remove instrument 

covers. Component replacement and internal 

adjustments must be made only by qualified 

personnel. 

Instruments that appear damaged or defective 

should be made inoperative and secured against 

unintended operation until they can be repaired by 

qualified service personnel.

The following general safety precautions must be 

observed during all phases of operation of this 

instrument. Failure to comply with these precautions 

or with specific warnings elsewhere in this manual 

violates safety standards of design, manufacture, 

and intended use of the instrument.

Agilent Technologies Inc. assumes no liability for 

the customer's failure to comply with these 

requirements.

Before operation, review the instrument and manual 

for safety markings and instructions. You must follow 

these to ensure safe operation and to maintain the 

instrument in safe condition.

This product is a Safety Class 1 instrument 

(provided with a protective earth terminal). 

The protective features of this product may be 

impaired if it is used in a manner not specified in 

the operation instructions.

All Light Emitting Diodes (LEDs) used in this 

product are Class 1 LEDs as per IEC 60825-1.

Environmental Conditions

Verify that all safety precautions are taken.

The power cable inlet of the instrument 

serves as a device to disconnect from the 

mains in case of hazard. 

The instrument must be positioned so that 

the operator can easily access the power 

cable inlet. When the instrument is rack-

mounted the rack must be provided with 

an easily accessible mains switch.

Before Applying Power

To minimize shock hazard, the instrument chassis 

and cover must be connected to an electrical 

protective earth ground. The instrument must be 

connected to the ac power mains through a 

grounded power cable, with the ground wire firmly 

connected to an electrical ground (safety ground) 

at the power outlet. Any interruption of the 

protective (grounding) conductor or disconnection 

of the protective earth terminal will cause a 

potential shock hazard that could result in 

personal injury.

Do not operate the instrument in the presence of 

flammable gases or fumes.

Do Not Operate in an Explosive Atmosphere

General Safety Precautions

General

Ground the Instrument

This instrument is intended for indoor use in an

installation category II, pollution degree 

2 environment. It is designed to operate within 

a temperature range of 5 – 40 °C (40 – 105 °F)

at a maximum relative humidity of 95% and 

at altitudes of up to 2000 meters.

Refer to the specifications tables for the ac mains 

voltage requirements and ambient operating 

temperature range.

Do Not Remove the Instrument Cover

This product is marked with a warning 

symbol when it is necessary for the user 

to refer the instructions in the manual. 

Instrument Markings 

Revision 7.0, October 2012

Manual Part Number

N4916B-91011

Printed in Germany

Agilent Technologies, Deutschland GmbH

Herrenberger Str. 130

71034 Boeblingen, Germany

Revision

© Agilent Technologies, Inc. 2012

Copyright

Technology Licenses

The hardware and/or software described in this 

document are furnished under a license and may 

be used or copied only in accordance with 

terms of such license.

The material contained in this document is provided 

“as is,” and is subject to being changed, without 

notice, in future editions. Further, to the maximum 

extent permitted by applicable law, Agilent disclaims 

all warranties, either express or implied, with regard 

to this manual and any information contained herein,

including but not limited to the implied warranties of 

merchantability and fitness for a particular purpose. 

Agilent shall not be liable for errors or for incidental 

or consequential damages in connection with the 

furnishing, use or performance of this document or 

of any information contained herein. Should Agilent 

and the user have a separate written agreement with 

warranty terms covering the material in this document 

that conflict with these terms, the warranty terms in 

the separate agreement shall control.

Restricted Rights Legend

Warranty

U.S. Government Restricted Rights.  

Software and technical data rights granted to 

the federal government include only those rights 

customarily provided to end user customers. 

Agilent provides this customary commercial license 

in Software and technical data pursuant to FAR 12.211 

(Technical Data) and 12.212 (Computer Software) and, 

for the Department of Defense, DFARS 252.227-7015 

(Technical Data - Commercial Items) and 

DFARS 227.7202-3 (Rights in Commercial Computer 

Software or Computer Software Documentation).

All front-panel connectors of N4916B are very sensitive

to Electrostatic Discharge (ESD). 

We urgently recommend to operate the instrument in

an electrostatic safe environment. 

There is a high risk of instrument damage causing 

expensive repairs when connecting a not fully 

discharged device or cable to a front-panel connectors 

or when touching a connector.

Please follow these instructions:

Before connecting any coaxial cable to the connectors, 

short the center and outer conductor with ground.

Before touching the front-panel connectors, discharge 

yourself by touching the properly grounded frame of 

the instrument.

ESD Sensitive Device

Содержание N4916B

Страница 1: ...nline Help of your High Performance Serial BERT N4903B For more information visit The Help also offers printable versions of the User Guide and the Programming Guide www agilent com find jbert You onl...

Страница 2: ...I pollution degree 2 environment It is designed to operate within a temperature range of 5 40 C 40 105 F at a maximum relative humidity of 95 and at altitudes of up to 2000 meters Refer to the specifi...

Страница 3: ...the installation media All data and clock input and output connectors of the PG that are not used in your test setup must be terminated with 50 Ohm The instrument can operate from any single phase AC...

Страница 4: ...ct the Agilent IO Control icon in the Windows task bar 5 If you see this icon the revision of the Agilent IO Libraries Suite is 15 5 or later You may wish to connect a keyboard and mouse to your Seria...

Страница 5: ...he rear USB ports of your N4903B 3 When you connect the N4916B for the first time the Windows Found New Hardware Wizard appears and asks whether it should connect to Windows Update Answer No 4 Click N...

Страница 6: ...e alias name to DATA_OUT or AUXDATA_OUT depending on the channel Data Out and Aux Data Out used This is the alias used by the software 3 After clicking OK the Agilent Connection Expert shows a window...

Страница 7: ...these functions 5 Enabling Clock Multiplier Select the Clock Multiplier function to open the Clock Multiplier Connection dialog 7 If you select the Clock Multiplier function a new menu entry is added...

Страница 8: ...For details see the Help and the User Guide Choose a suitable pattern e g PRBS and start the pattern generator 9 After some adjustments of the scope you will see a display like the following 10 In ca...

Страница 9: ...of problems please refer to the section Problems with the N4916B of the Help and the User Guide of your N4903B Preset the instrument state 1 Preset the instrument state 1 Enable Clock Multiplier from...

Отзывы: