Installing the Agilent N4916B

Establish the USB Connection

Keep the user interface of 
the Serial BERT N4903B 
minimized.

1

Connect the N4916B to 
mains and switch it on.

2

Connect the USB cable between 
the USB port of the N4916B and 
one of the rear USB ports of your
N4903B.

3

When you connect the N4916B 
for the first time, the Windows 

Found New Hardware Wizard

 

appears and asks whether it should 
connect to 

Windows Update

.

Answer 

No

.

4

Click 

Next 

until 

the wizard finishes.

5

Windows will automatically 
identify the N4916B as a 

USB 

Test and Measurement Device

.

The necessary USB driver is part 
of the Agilent IO Libraries Suite.

5

Rear panel view of N4903B

Rear panel view of N4916B

Содержание N4916B

Страница 1: ...nline Help of your High Performance Serial BERT N4903B For more information visit The Help also offers printable versions of the User Guide and the Programming Guide www agilent com find jbert You onl...

Страница 2: ...I pollution degree 2 environment It is designed to operate within a temperature range of 5 40 C 40 105 F at a maximum relative humidity of 95 and at altitudes of up to 2000 meters Refer to the specifi...

Страница 3: ...the installation media All data and clock input and output connectors of the PG that are not used in your test setup must be terminated with 50 Ohm The instrument can operate from any single phase AC...

Страница 4: ...ct the Agilent IO Control icon in the Windows task bar 5 If you see this icon the revision of the Agilent IO Libraries Suite is 15 5 or later You may wish to connect a keyboard and mouse to your Seria...

Страница 5: ...he rear USB ports of your N4903B 3 When you connect the N4916B for the first time the Windows Found New Hardware Wizard appears and asks whether it should connect to Windows Update Answer No 4 Click N...

Страница 6: ...e alias name to DATA_OUT or AUXDATA_OUT depending on the channel Data Out and Aux Data Out used This is the alias used by the software 3 After clicking OK the Agilent Connection Expert shows a window...

Страница 7: ...these functions 5 Enabling Clock Multiplier Select the Clock Multiplier function to open the Clock Multiplier Connection dialog 7 If you select the Clock Multiplier function a new menu entry is added...

Страница 8: ...For details see the Help and the User Guide Choose a suitable pattern e g PRBS and start the pattern generator 9 After some adjustments of the scope you will see a display like the following 10 In ca...

Страница 9: ...of problems please refer to the section Problems with the N4916B of the Help and the User Guide of your N4903B Preset the instrument state 1 Preset the instrument state 1 Enable Clock Multiplier from...

Отзывы: