Using
an
External
Controller
Y
ou
can
use
an
external
controller
to
control
the
analyzer
by
using
the
GPIB
interface
on
the
rear
panel.
Connect
the
controller
and
the
analyzer
using
an
GPIB
cable
.
1.
Connecting
External
GPIB
Cables
Connect
the
analyzer
and
external
instruments
with
GPIB
cables
.
The
GPIB
connector
is
on
the
rear
panel
of
the
analyzer
.
The
rules
for
connecting
GPIB
cables
are
as
follows:
The
total
number
of
GPIB
devices
can
be
up
to
15
instruments
.
The
total
length
of
all
the
cables
used
can
be
up
to
20m
or
2m
for
each
instrument.
Y
ou
can
connect
the
GPIB
cables
in
any
conguration
(linear
,
star
,
or
combination),
as
long
as
the
above
rules
are
satised.
Note
Do
not
use
a
screwdriver
when
connecting
the
GPIB
cables
.
The
screwdriver
slots
in
the
lock
screws
are
provided
for
REMO
V
AL
only
.
2.
Setting
the
GPIB
A
ddress
The
analyzer
has
no
hardware
switch
for
setting
the
GPIB
address
.
Y
ou
can
only
set
it
by
front
panel
operation.
T
o
change
the
GPIB
address
of
the
analyzer
,
perform
the
following
steps:
1.
Press
4
System
5
NNNNNNNNNNNNNN
GPIB
.
2.
Press
NNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNN
ADDRESS:
E5100A
or
NNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNN
ADDRESS:
E5100B
.
3.
Enter
the
new
address
by
using
the
numerical
keys
.
(A
void
duplication
with
the
GPIB
address
of
the
external
controller
.)
4.
Press
NNNNNNNN
x1
to
complete
the
operation.
When
you
want
to
control
another
E5100A/B ,
change
the
GPIB
address
to
avoid
duplication
of
addresses
on
the
same
bus
.
When
the
analyzer
receives
any
GPIB
command
from
an
external
controller
,
NNNNNNNNNNNNNNNNN
Local
is
appeared
on
the
display
to
indicate
the
analyzer
is
in
the
remote
mode
.
In
remote
mode
,
front
panel
key
operation
is
disabled.
T
o
cancel
the
remote
mode
,
press
the
NNNNNNNNNNNNNNNNN
Local
.
3.
Preparing
F
or
HP
B
ASIC
Operation
T
o
prepare
HP
B
ASIC
for
operation,
see
your
HP
B
ASIC
system
manual.
Introduction
1-7
Содержание E5100A
Страница 1: ...Agilent E5100A B Network Analyzer Programming Manual ...
Страница 2: ......
Страница 5: ...c Copyright 1995 1996 1997 1998 2000 2001 Agilent Technologies Japan Ltd ...
Страница 8: ......
Страница 36: ......
Страница 46: ......
Страница 48: ...Figure 3 1 Simpli ed Data Processing Flow 1 3 2 Data Processing and T ransfer ...
Страница 58: ......
Страница 76: ......
Страница 105: ...610 RETURN 620 630 Ending ENDING PROGRAM 640 ASSIGN Dt TO 650 660 END Application Sample Programs 7 7 ...
Страница 112: ......
Страница 232: ......
Страница 246: ......
Страница 250: ......
Страница 277: ...110 PRINT Pole left Pole1 dB Fp1 Hz 120 PRINT Pole right Pole2 dB Fp2 Hz 130 END Waveform Analysis Commands D 27 ...
Страница 299: ...110 END Waveform Analysis Commands D 49 ...
Страница 302: ......
Страница 322: ......
Страница 350: ......
Страница 352: ......
Страница 362: ......
Страница 368: ......
Страница 372: ......