
Conventions
and
Denitions
This
section
describes
the
conventions
and
denitions
that
are
used
to
describe
the
waveform
analysis
commands
.
1
!
ANARANG
2
!
Sets
the
stimulus
range
for
the
waveform.
.
.
.
3
!
Syntax
ANARANG
start, stop
4
!
Where
,
0
start
Start
value
of
the
analysis
range
1
stop
Stop
value
of
the
analysis
range
5
!
Query
Response
6
!
Semantics
7
!
Note
8
!
Examples
1
Command
name
.
2
Command
description.
3
Command
syntax
This
part
shows
the
syntax
of
the
command.
Y
ou
must
put
a
space
between
the
command
and
the
parameters
.
4
Command
parameter
description
The
rst
column
of
the
table
lists
the
register
number
that
is
used
by
the
EXECUTE
command.
Y
ou
must
put
the
parameter
in
the
indicated
register
before
using
the
EXECUTE
command.
F
or
example
(in
the
above
case):
WRITEIO
15,0;Start
Put
\Start"
in
register
0.
WRITEIO
15,1;Stop
Put
\Stop"
in
register
1.
EXECUTE
"ANARANG"
Execute
\ANARANG".
The
second
column
lists
the
parameter
name
that
is
shown
in
the
Syntax
area.
The
third
column
describes
the
parameters
.
5
Query
response
.
This
part
shows
what
values
will
be
returned
as
the
query
response
.
The
description
of
the
query
response
is
similar
to
the
description
of
the
Syntax
area
shown
above
.
6
Semantics
This
part
describes
how
the
command
obtains
the
values
for
the
query
response
.
7
Note
This
part
describes
the
required
conditions
or
limitations
when
using
the
command.
8
Examples
This
part
shows
examples
of
how
to
use
the
command.
Examples
are
provided
for
both
HP
B
ASIC
on
an
external
controller
and
Instrument
B
ASIC
on
the
analyzer
.
D-2
Waveform
Analysis
Commands
Содержание E5100A
Страница 1: ...Agilent E5100A B Network Analyzer Programming Manual ...
Страница 2: ......
Страница 5: ...c Copyright 1995 1996 1997 1998 2000 2001 Agilent Technologies Japan Ltd ...
Страница 8: ......
Страница 36: ......
Страница 46: ......
Страница 48: ...Figure 3 1 Simpli ed Data Processing Flow 1 3 2 Data Processing and T ransfer ...
Страница 58: ......
Страница 76: ......
Страница 105: ...610 RETURN 620 630 Ending ENDING PROGRAM 640 ASSIGN Dt TO 650 660 END Application Sample Programs 7 7 ...
Страница 112: ......
Страница 232: ......
Страница 246: ......
Страница 250: ......
Страница 277: ...110 PRINT Pole left Pole1 dB Fp1 Hz 120 PRINT Pole right Pole2 dB Fp2 Hz 130 END Waveform Analysis Commands D 27 ...
Страница 299: ...110 END Waveform Analysis Commands D 49 ...
Страница 302: ......
Страница 322: ......
Страница 350: ......
Страница 352: ......
Страница 362: ......
Страница 368: ......
Страница 372: ......