Register
P
arameter
Description
0
Loss
Insertion
loss
1
Loss
c
Const
Loss
2
B
W
x
1
dB
down
bandwidth
3
f
cent
Center
frequency
4
Q
Q
5
P
ass
P
assband
ripple
6
R
eject
Rejection
level
7
Spurious
Spurious
level
8
P
ole
x1
First
negative
peaks
found
to
the
left
of
the
maximum
point.
9
P
ole
stim1
Stimulus
of
P
ole
x1
.
10
P
ole
x2
First
negative
peak
found
to
the
right
of
the
maximum
point.
11
P
ole
stim2
Stimulus
of
P
ole
x2
.
12
1f
left
Frequency
dierence
between
the
left
cuto
point
(f
cl
)
and
the
middle
of
the
range
.
13
1f
right
Frequency
dierence
between
the
right
cuto
point
(f
cr
)
and
the
middle
of
the
range
.
14
1f
left2
Frequency
dierence
between
the
left
cuto
point
(f
cl2
)
and
the
middle
of
the
range
.
15
1f
right2
Frequency
dierence
between
the
right
cuto
point
(f
cr2
)
and
the
middle
of
the
range
.
.
.
.
.
.
.
.
.
.
2n+10.
1f
left
n
Frequency
dierence
between
the
left
cuto
point
(f
cl
n
)
and
the
middle
of
the
range
.
2n+11.
1f
right
n
Frequency
dierence
between
the
right
cuto
point
(f
cr
n
)
and
the
middle
of
the
range
.
Semantics
Insertion
loss
,
constant
loss
,
x
1
dB
bandwidth,
Center
frequency
,
Q,
passband
ripple
,
rejection
level,
spurious
level,
P
ole
x1
,
P
ole
stim1
,
P
ole
x2
are
the
same
as
the
responses
of
OUTPCFILT?
.
1f
left
n
and
1f
right
n
are
the
frequency
dierences
between
both
sides
at
the
x
n
dB
down
cuto
points
(f
cl
n
and
f
cr
n
)
and
f
c
.
Note
If
both
of
the
two
x
1
dB
down
cuto
points
are
not
found,
the
analyzer
returns
0
for
all
values
of
the
query
response
.
If
both
of
the
two
x
n
dB
down
cuto
points
are
not
found,
the
analyzer
returns
0
for
1f
left
n
and
1f
right
n
.
If
the
corresponding
peak
for
POLE?
is
not
found,
the
analyzer
returns
0
for
P
ole
x1
,
P
ole
stim1
,
P
ole
x2
,
and
P
ole
stim2
.
Examples
10
ASSIGN
@E5100
TO
717
20
OUTPUT
@E5100;"CENS
70MHz,100kHz"
30
OUTPUT
@E5100;"SING?"
40
ENTER
@E5100;Tmp
50
OUTPUT
@E5100;"ANAOCH1;ANARFULL;ANAODATA"
60
OUTPUT
@E5100;"OUTPCF2?
70MHz,-50,69.98MHz,70.02MHz,-3,-10,-20"
D-34
Waveform
Analysis
Commands
Содержание E5100A
Страница 1: ...Agilent E5100A B Network Analyzer Programming Manual ...
Страница 2: ......
Страница 5: ...c Copyright 1995 1996 1997 1998 2000 2001 Agilent Technologies Japan Ltd ...
Страница 8: ......
Страница 36: ......
Страница 46: ......
Страница 48: ...Figure 3 1 Simpli ed Data Processing Flow 1 3 2 Data Processing and T ransfer ...
Страница 58: ......
Страница 76: ......
Страница 105: ...610 RETURN 620 630 Ending ENDING PROGRAM 640 ASSIGN Dt TO 650 660 END Application Sample Programs 7 7 ...
Страница 112: ......
Страница 232: ......
Страница 246: ......
Страница 250: ......
Страница 277: ...110 PRINT Pole left Pole1 dB Fp1 Hz 120 PRINT Pole right Pole2 dB Fp2 Hz 130 END Waveform Analysis Commands D 27 ...
Страница 299: ...110 END Waveform Analysis Commands D 49 ...
Страница 302: ......
Страница 322: ......
Страница 350: ......
Страница 352: ......
Страница 362: ......
Страница 368: ......
Страница 372: ......