![Agilent Technologies 86120C Скачать руководство пользователя страница 123](http://html.mh-extra.com/html/agilent-technologies/86120c/86120c_user-manual_2867947123.webp)
3-45
Programming
Lists of Commands
:CALCulate3:DELTa:REFerence[:WAVelength]
Selects the signal to be used as the reference for the
DELTa calculations.
I
:CALCulate3:DELTa:REFerence:WNUMber
Selects the signal to be used as the reference for the
DELTa calculations.
I
:CALCulate3:DELTa:WAVelength[:STATe]
Turns the delta wavelength measurement mode on and off.
I
:CALCulate3:DELTa:WPOWer[:STATe]
Turns the delta wavelength and power measurement mode
on and off.
I
:CALCulate3:DRIFt:DIFFerence[:STATe]
Sets the drift calculation to subtract the minimum values
measured from the maximum values measured.
I
:CALCulate3:DRIFt:MAXimum[:STATe]
Sets the drift calculation to return the maximum power
(frequency) values measured.
I
:CALCulate3:DRIFt:MINimum[:STATe]
Sets the drift calculation to return the minimum power
(frequency) values measured.
I
:CALCulate3:DRIFt:PRESet
Turns off all the drift states for DIFFerence, MAXimum,
MINimum, and REFerence.
I
:CALCulate3:DRIFt:REFerence:RESet
Places the current list of signals into the reference list.
I
:CALCulate3:DRIFt:REFerence[:STATe]
Turns the drift state on and off so that CALC3:DATA? will
return the reference signal list.
I
:CALCulate3:DRIFt[:STATe]
Turns the drift measurement calculation on and off.
I
:CALCulate3:FPERot[:STATe]
Turns the Fabry-Perot measurement mode on and off.
I
:CALCulate3:FPERot:MEAN:[WAVelength]?
Queries the mean wavelength of the selected modes.
I
:CALCulate3:FPERot:MEAN:FREQuency?
Queries the mean frequency of the selected modes.
I
:CALCulate3:FPERot:MEAN:WNUMber?
Queries the mean wavenumber of the selected modes.
I
:CALCulate3:FPERot:PEAK:[WAVelength]?
Queries the peak wavelength of the selected modes.
I
:CALCulate3:FPERot:PEAK:FREQuency?
Queries the peak frequency of the selected modes.
I
:CALCulate3:FPERot:PEAK:WNUMber?
Queries the peak wavenumber of the selected modes.
I
:CALCulate3:FPERot:PEAK:POWer?
Queries the peak power of the selected modes.
I
:CALCulate3:FPERot:FWHM:[WAVelength]?
Queries full width half-max wavelength of selected modes.
I
:CALCulate3:FPERot:FWHM:FREQuency?
Queries full width half-max frequency of selected modes.
I
:CALCulate3:FPERot:FWHM:WNUMber?
Queries full width half-max wavenumber of selected
modes.
I
:CALCulate3:FPERot:MODE:SPACing:[WAVelengt
h]?
Queries the mode spacing wavelength of the selected
modes.
I
:CALCulate3:FPERot:MODE:SPACing:FREQuenc
y?
Queries the mode spacing frequency of the selected
modes.
I
:CALCulate3:FPERot:MODE:SPACing:WNUMbe
r?
Queries the mode spacing wavenumber of the selected
modes.
I
Table 3-10. Programming Commands (3 of 5)
Command
Description
Code
Codes: S indicates a standard SCPI command. I indicates an instrument specific command.
Содержание 86120C
Страница 12: ......
Страница 26: ...1 14 Getting Started Returning the Instrument for Service ...
Страница 27: ...1 15 Getting Started Returning the Instrument for Service ...
Страница 28: ......
Страница 96: ...3 18 Programming Monitoring the Instrument ...
Страница 128: ...3 50 Programming Lists of Commands ...
Страница 158: ...4 30 Programming Commands CALCulate1 Subsystem Query Response For normal update 15 047 For fast update 7 525 ...
Страница 236: ...4 108 Programming Commands UNIT Subsystem ...
Страница 248: ......
Страница 262: ...6 14 Specifications and Regulatory Information Declaration of Conformity Declaration of Conformity ...
Страница 264: ...6 16 Specifications and Regulatory Information Product Overview ...
Страница 269: ...7 5 Reference Menu Maps Appl s Menu ...
Страница 271: ...7 7 Reference Menu Maps Display List by WL Menu Delta On Menu ...
Страница 273: ...7 9 Reference Menu Maps System Print Menu ...
Страница 274: ...7 10 Reference Menu Maps System Setup Menu ...
Страница 284: ......
Страница 292: ......
Страница 293: ......