![Agilent Technologies 2000 X Скачать руководство пользователя страница 282](http://html.mh-extra.com/html/agilent-technologies/2000-x/2000-x_user-manual_2868572282.webp)
282
Agilent InfiniiVision 2000 X-Series Oscilloscopes User's Guide
21
Reference
Binary Data in MATLAB
Binary data from an InfiniiVision oscilloscope can be imported to The
MathWorks MATLAB®. You can download the appropriate MATLAB
functions from the Agilent Technologies web site at
"www.agilent.com/find/2000X- Series- examples"
.
Agilent provides the .m files, which need to be copied into the work
directory for MATLAB. The default work directory is C:\MATLAB7\work.
Binary Header Format
File Header
There is only one file header in a binary file. The file header consists of
the following information.
Waveform Header
It is possible to store more than one waveform in the file, and each
waveform stored will have a waveform header. When using segmented
memory, each segment is treated as a separate waveform. The waveform
header contains information about the type of waveform data that is
stored following the waveform data header.
Cookie
Two byte characters, AG, that indicate the file is in the Agilent Binary Data file
format.
Version
Two bytes that represent the file version.
File Size
A 32-bit integer that is the number of bytes that are in the file.
Number of
Waveforms
A 32-bit integer that is the number of waveforms that are stored in the file.
Header Size
A 32-bit integer that is the number of bytes in the header.
Waveform Type
A 32-bit integer that is the type of waveform stored in the file:
• 0 = Unknown.
• 1 = Normal.
• 2 = Peak Detect.
• 3 = Average.
• 4 = Not used in InfiniiVision oscilloscopes.
• 5 = Not used in InfiniiVision oscilloscopes.
• 6 = Logic.
Содержание 2000 X
Страница 1: ...s1 Agilent InfiniiVision 2000 X Series Oscilloscopes User s Guide ...
Страница 18: ...18 Agilent InfiniiVision 2000 X Series Oscilloscopes User s Guide ...
Страница 42: ...42 Agilent InfiniiVision 2000 X Series Oscilloscopes User s Guide 1 Getting Started ...
Страница 62: ...62 Agilent InfiniiVision 2000 X Series Oscilloscopes User s Guide 3 Vertical Controls ...
Страница 76: ...76 Agilent InfiniiVision 2000 X Series Oscilloscopes User s Guide 4 Math Waveforms ...
Страница 100: ...100 Agilent InfiniiVision 2000 X Series Oscilloscopes User s Guide 6 Digital Channels ...
Страница 106: ...106 Agilent InfiniiVision 2000 X Series Oscilloscopes User s Guide 7 Display Settings ...
Страница 134: ...134 Agilent InfiniiVision 2000 X Series Oscilloscopes User s Guide 9 Triggers ...
Страница 142: ...142 Agilent InfiniiVision 2000 X Series Oscilloscopes User s Guide 10 Trigger Mode Coupling ...
Страница 168: ...168 Agilent InfiniiVision 2000 X Series Oscilloscopes User s Guide 12 Cursors ...
Страница 204: ...204 Agilent InfiniiVision 2000 X Series Oscilloscopes User s Guide 15 Digital Voltmeter ...
Страница 216: ...216 Agilent InfiniiVision 2000 X Series Oscilloscopes User s Guide 16 Waveform Generator ...
Страница 230: ...230 Agilent InfiniiVision 2000 X Series Oscilloscopes User s Guide 17 Save Recall Setups Screens Data ...
Страница 236: ...236 Agilent InfiniiVision 2000 X Series Oscilloscopes User s Guide 18 Print Screens ...
Страница 272: ...272 Agilent InfiniiVision 2000 X Series Oscilloscopes User s Guide 20 Web Interface ...
Страница 290: ...290 Agilent InfiniiVision 2000 X Series Oscilloscopes User s Guide 21 Reference ...