29
Australia
Gas Connection
The Gas supply needs to terminate with a down facing
connection. The rear cover boxes limit the position of
the supply point.
view from the back
A
position for gas supply connector
B
appliance gas inlet
Because the height of the cooker can be adjusted and
each connection is different it is difficult to give precise
dimensions. Ideally the house supply connection
should be in the shaded area shown in the diagram.
Means of isolation must be provided at the supply point
by either an approved quick-connect device or a Type
1 manual shut-off valve. The hose should be fitted so
that both inlet and outlet connections are vertical so
that the hose hangs downwards in a ‘U’ shape.
The connector is located just below the hotplate level
at the rear of the cooker.
A flexible connection is supplied with the cooker. If it is
necessary to use another hose it must be to A.S. 1869
class B and suitable for your gas type. If in doubt
contact, your supplier.
To prevent strain on the connections to the cooker the
restraining chain should be used. Securely fix the
supplied wall bracket to the fabric of the building and
clip the supplied restraining chain to the bracket.
After completing the gas connection, check the cooker
is gas sound with a pressure test. When checking for
gas leaks do not use washing up liquid - this can
corrode. Use a product specifically manufactured for
leak detection.
Natural Gas
The adjustable spring loaded governor is pre-set to
give a nominal pressure of 1kPa on NG. Connect to the
Rp
1
/
2
inlet on the underside of the governor.
Propane
This cooker is supplied ready for use on natural gas. A
conversion kit for Propane gas is supplied with the
cooker - see the conversion instructions in the next
section.
Pressure testing
Pull the cooker forward, if necessary, to gain access to
the rear.
The pressure test point is accessible on the connector
block at the upper right hand rear. Remove the test
nipple screw and fit a pressure gauge to the test point.
See Technical data section at the back of this book for
test pressures.