SETTING UP THE TIMING PARAMETER
Press
“ .” Press for the first time and the timing function turns on, the LCD screen
displays , the
stove’s indicator lights green. Press again to turn off, icon
on the LCD screen goes off. After the timing function is turned on, it works according
the parameter settings. The LCD screen
lights up according to corresponding parameter settings;
Note: when the time, week and timing parameters are changed, you need to switch on-off the
timing key to transfer the timing parameters to the machine. After the machine has received
them correctly, the buzzer will beep once.
10. SETTING UP THE OPEN WINDOW CONTROL
Press“
”. Press once to turn on the Open Window function, the LCD screen displays
icon
, the indicator
on the stove lights yellow. Press again to turn it off, the LCD
screen does not display icon
and the indicator
on the stove goes off. The buzzer
beeps when the key is pressed;
After the Open Window function is turned on, the program firstly detects if the heating
function is turned on. If it is turned on, the program will save the current ambient temperature
value and detects the ambient temperature change once per 12 minutes. When the decrease
in the ambient temperature detected within 30 minutes exceeds 4
℃
, the program will deem
that the window is open and stop heating, and the Open Window indicator
on the stove
will flash rapidly. After it has stopped heating for 70 minutes, the program starts to detect if the
window is closed, and the indicator
flashes slowly. It heats for 6 minutes every 30
minutes (position H2). If the temperature rise is more than 2
℃
, the window is considered as
closed, and the indicator
℃
stops flashing.