EN 5
AFPUMPS S.r.l.
E-mail: [email protected]
h p:// www.afpumps.com
Tel. +39 0429 77 82 95 - Fax +39 0429 76 30 49
Overall dimensions and packaging.
L
2
L
L
M
L
1
Model
Propeller
L
L
1
L
2
L
M
H
1
A
1
B
1
Kg.
MIX 75-6
Ø 230
420
470
225
380
540
310
210
24
MIX 100-4
MIX 150-4
Ø 210
443
493
225
403
540
310
210
24
ELECTRICAL CONNECTION
The electrical connec on must always be carried out by qualifi ed personnel,
respec ng the local legal regula ons. Make sure that the voltage and frequency of
the power supply line correspond to those indicated on the nameplate of the mixer.
Make sure that the power supply line has an effi cient earth system and connect the
mixer to earth.
The power supply cable must never in any way be stressed, pulled or bent with sharp bends. During
installa on, make sure that the free end of the power cable is never immersed in water and that it is
well protected against possible infi ltra on of water or humidity.
Par cular a en on must be paid to the integrity of the cable: even small abrasions can cause
infi ltra on into the electric motor. In the event of any damage to the power supply cable, it is
preferable to replace it rather than repair it: always use qualifi ed personnel in any case.
When using extensions, the junc on must remain dry and, to avoid excessive voltage drops, the
cable must have an adequate sec on.
It is always necessary to install adequate electrical protec on
(suitably calibrated magnetothermic
switch and diff eren al switch with tripping current lower than 30 mA)
capable of ensuring omnipolar
disconnec on from the mains with a contact opening distance of at least 3 mm.
Before any maintenance and / or repair of the mixer, disconnect the power supply.
The maximum allowable devia on between the actual power supply voltage and the nominal value
indicated on the mixer plate is ± 10% (three-phase).