EN 3
AFPUMPS S.r.l.
E-mail: [email protected]
h p:// www.afpumps.com
Tel. +39 0429 77 82 95 - Fax +39 0429 76 30 49
To prevent damage to the eyes and skin, observe the following rules when working on the mixer:
• Always use safety goggles and rubber gloves.
• Rinse the mixer well with a hot pressure washer before star ng the opera on.
• Rinse the various components with clean water a er having disassembled them.
• Keep a rag around the oil chamber screw when you need to unscrew it to prevent any splashes
from reaching your eyes or skin if pressure has built up in the mixer due to infi ltra on of mixed
liquid.
Do the following if harmful chemicals come into contact.
With your eyes:
• Rinse immediately with running water for 15 minutes, keeping the eyelids wide open.
• Contact an ophthalmologist.
With your skin:
• Remove contaminated clothes, wash your skin with soap and water, if necessary get checked by
a doctor.
FOLLOW ALL THE RULES OF HYGIENE AND SAFETY AS WELL AS ANY LOCAL ORDINANCES.
INSTALLATION - Li ing equipment
To li the mixer, special equipment is required, it must be able to li the mixer and lower it into the
tank, possibly without the need for a recovery.
The minimum distance between the li ing hook and the edge of the pool must be according to pag.
9-10 to have the possibility to extract the mixer from the tank.
Oversized li ing equipment could cause damage to the mixer if it gets stuck during li ing opera ons.
Make sure that the anchoring of the li ing equipment is safe.
ATTENTION! Keep away from suspended loads.
INSPECTION
Periodic checks and preven ve maintenance ensure safer opera on over me.
The mixer must be inspected at least once a year and, in case of opera on in par cularly severe
condi ons, it is necessary to perform the inspec on more frequently, on this occasion it is necessary
to check the state of the oil.
Under normal opera ng condi ons, it is advisable to have the mixer overhauled in an authorized
workshop every three years.
OIL CHANGE
The oil chamber is fi lled in the factory; if there are traces of water or a light emulsion, it is necessary
to change the oil. It is necessary to remove the mixer from the well, the oil cap is located on the side
of the oil chamber, we recommend carrying out the opera on at an authorized workshop.
ATTENTION! In the event of leaks from the seal, the oil chamber may be under pressure.
To prevent splashing, hold a rag around the oil tank screw when you unscrew it.
Unscrew the closing cap of the oil chamber and drain the oil completely, then fi ll with the prescribed
amount of lubricant (see Table 1), close carefully and always replacing the same copper washer.
If you no ce obvious traces of water or if the oil is heavily emulsifi ed, check the lower mechanical
seal if necessary, replace it, or contact an authorized workshop.