pulsAR
radio Operator's Manual
D-2
SHEET OF
REV
DRAWING NO.
TITLE
DRAWN BY
CHECKED BY
DATE
DATE
APPROVED
DATE
APPROVED
DATE
SCALE
CAT5 ETHERNET & POWER CABLE
CBL-0503-XXX
B
1
1
NONE
J. Becker
9/15/03
APPLICATION
REVISION
NEXT ASSY USED ON REV
DESCRIPTION
DATE
APPROVAL
8 Pin Field Connector, Female
Lumberg USA
0321 08 or 0322 08 (fig. A)
3
MATERIAL
Plug Connector, 8 Cond., RJ45-type
Allen Tel
AT8X8SC-2224
2
Cable, CAT5, Outdoor, Solid Cond.
CommScope
5EXH04P24-BK-R-CMS-PV
1
DESCRIPTION
MANUFACTURER
PART NO.
ITEM
NOTES:
1. Use proper crimp tool for Item #2 connection
2. Remove cable filler gel from conductors before inserting into Item #2.
3. Insure that all eight conductors reach to end of interior channel before crimping Item #2.
4. Add label near item #2 “Afar Communications / CBL-0503-XXX” where XXX is cable length in feet.
For cables shorter than 3 ft, the length is shown as AXX where XX is in inches.
AFAR Communications, Inc.
A
J.B
Initial Release
09/15/03
1 8
RJ 45 Plug
ITEM #2
ITEM #3
WHT/ORN
ORN
WHT/GRN
BLUE
WHT/BLUE
GRN
WHT/BRN
BRN
ITEM #1
W/BLU
W/GRN
GRN
ORN
W/BRN
BLU
BRN
W/ORN
BRN
NO TAB SIDE
1
7
2
3
4
6
W/ORN
8
Solder Cups
REAR VIEW
5
RADIO 1
RADIO_ETH_TX- 2
RADIO
3
VDC 4
VDC 5
RADIO_ETH_RX- 6
GND 7
GND 8
1
7
2
3
5
4
8
6
Fig. A
Five pin connector is shown. Use same process for 8 pin.
Cable Length (in feet or inches) specified in part number
CBL-0503-050 for a 50 feet cable
CBL-0503-A20 for a 20 inch cable (use for cables shorter than 3 ft)
B
N.
B
Added short lengths
05/10/05
Содержание AR-24010E
Страница 2: ......
Страница 74: ...pulsAR radio Operator s Manual 4 26 ...
Страница 96: ...pulsAR radio Operator s Manual B 2 ...
Страница 101: ...pulsAR radio Operator s Manual D 3 ...