pulsAR
radio Operator's Manual
the source. Note that the “.bze” extension is required in the command. The download
“method” must be “binary” (which is the default).
Example:
>download C:\load\pmp03_12.bze
download the file pmp03_12.bze from the PC directory C:\load into the unit file
flash/pmp03_12
If the download is executed from a terminal connected to the Auxiliary port, the file is in ASCII
format and has the extension .dwe. The download method must be “inline”. The source
parameter is not needed since, after issuing the command, you must initiate the transfer of the
file from the terminal.
Example:
>download destination=pmp03_12 method=inline
After issuing the command initiate the file transfer using the terminal facilities.
run-file
filename=filename
Executes the specified file. The file is first copied into RAM and then the program is executed
out of RAM. If the radio is rebooted or power cycled, the radio reverts back to the program
defined as the default program. If the memory location is not defined (flash or tmp), the
command assumes the flash directory.
Examples:
>run pmp03_04
set-default-program
filename=filename
Sets the specified file as the default program to be loaded upon reboot or power cycle. Since
the default program must reside in flash memory, the “flash/” prefix is assumed and is not
required for the command.
Examples:
>sdp pmp03_04
4.8 Event Logging Commands
The
pulsAR radio
keeps track of various significant events in an “event log”. This event log holds up
to 500 events. The first 100 entries in the log are filled sequentially after power up and are not
overwritten. The remaining 400 entries consist of the last 400 events recorded. All events are time-
tagged with system time.
Events are classified in different categories from level 0 (catastrophic error) to 7 (information).