pulsAR
radio Operator's Manual
>
command value
For example the command:
>
save-configuration destination=main
can be shortened to any of the following:
>
save-configuration main
>
save main
>
save
Not all parameters associated with a command need to be specified. Depending on the command,
when a parameter is omitted it either assumes a default value or keeps the last value assigned to
that parameter.
For all parameters that accept a numeric value, the number can be entered in decimal or
hexadecimal notation. To enter a number in hexadecimal notation precede it with a 0x or 0X. All
other numeric values are interpreted as decimal. Example:
>
rf-1 receive=0x1a
(hexadecimal)
>
rf-1 receive=14
(decimal)
The following sections describe the various commands grouped according to their functionality. A
summary list of all commands are contained in Appendices A and B.
4.3 Configuration Management Commands
A
radio configuration
consists of a set of programmable parameters that define the radio operation
with regard to a variety of operating modes. There are five different configurations identified as
current, main, alternate, factory
and
basic
.
The
main
and
alternate
configurations are both stored in non-volatile memory. They can be loaded
into the
current
configuration with the
load
command. On power up the radio loads the
main
configuration from non-volatile memory into the current configuration.
The
current
configuration is the set of parameters currently being used and can be modified by the
operator through several commands. This configuration is volatile. If the current configuration has
been modified it should be saved using the
save
command. Otherwise the modifications will be lost
if power is removed.
The
factory
configuration can not be modified by the operator and is used to return the radio to the
factory default condition. It is useful as a starting point to create a customized configuration.
The
basic
configuration is similar to the factory configuration with the exception that a few
parameters are left unchanged when you issue the
load basic
command. The parameters left
unchanged are the IP and RF-1 configurations. This is useful when you are logged on to a remote
unit and need to start from a known configuration. If you were to issue the
load factory
command
you might lose contact with the remote unit if, for example, it changes the radio channel of the remote
radio.
The access to change the radio configuration can be password protected. This password is set by the
user with the
change-password
command. Once a password is set, issue the
lock
command to
4-3