  BESA-12P                                                                                                      User’s manual 

 

-

 52 -

 

www.aetool.com

AETOOL LTD.

Page 23

The software will start to install and prompt. See example below. 
 
 
 
 
 
 
 
 

 
 
 
 
 
 

 
 

  Click 

“OK” tab to continue the installation and the software is 

successfully installed. 

 

Once the software has been installed, the icon              will appear on 

the desktop. 

 

 

 
Step 5. 

Back to desktop, open BESA program by left clicking the                                 
            and the display page will show as follows: 
 

 
 
 
 
 
 
 
 
 
 
 
 
 

 

 
 

Step 6.

 

Now link up BESA-12P with PC through the following procedures: 

 

1.  On the Main Menu page (Fig. 83) below, select Setup Menu by 

pressing            key to highlight it and then press            key. 

 

 

It will 
automatically 
detect COM port 
in used. 
 
If you find that 
this field is blank, 
unplug 
BESA-12P`s 
USB cable then 
plug again. The 
COM Port will 
appear. 
 

 

Click here to select your 
preferred language from the 10 
different languages. 
 

 

Click here to insert your 
Company Name & address. 

 

Содержание BESA-12P

Страница 1: ...BESA 12P User s manual 1 www aetool com AETOOL LTD BESA 12P V13 08 Battery Electrical System Analyser with integrated Printer USER MANUAL...

Страница 2: ...Link 13 6 0 HELP Key 14 7 0 Battery Test 7 1 Start Testing 16 8 0 Battery Rating Charts 8 1 Japanese Industrial Standards JIS Rating Chart 29 8 2 DIN EN Standards Rating Charts 30 8 3 YUASA Battery R...

Страница 3: ...Analyses the condition of the electrical return circuit contacts resistance which were connected to the engine or chassis body from the battery terminal with results and recommendations display after...

Страница 4: ...ipped with an USB port to be connected to the PC to store the results or have it printed out from normal computer printer 1 2 Specifications Operating Voltage 9V 15V DC max Analysing Capacity Amps CCA...

Страница 5: ...es they are hazardous that can lead to death To protect your eyes from propellant object such as caustic liquids always wear safety eye protection Fuel and battery vapors are highly flammable DO NOT S...

Страница 6: ...m 9V 15V DC and should not be tested on 24V directly It will cause damage the unit For 12V x 2 batteries in series or parallel disconnect the connections and test them individually Battery that has ju...

Страница 7: ...d exercise caution Do not allow battery electrolyte to mix with salt water Even small quantities of this combination will produce chlorine gas that can KILL you Whenever possible please follow the man...

Страница 8: ...the battery and charger manufacturer s procedures for connecting and disconnecting cables and other steps to minimize the possibility of an explosion or incorrectly charging the battery You should tur...

Страница 9: ...rical System Analyser 4 1 BESA 12P 4 2 Keypad Functions Figure 1 Figure 2 3 6 8 1 2 4 7 5 Red Clamp to battery positive post Black Clamp to battery negative post USB port for connection to PC Printer...

Страница 10: ...ery Ratings values mode press this key once will decrease the value by step of 5 units 4 Use this key to shift the selection tab to the left item OR when it is in the keying in Battery Ratings values...

Страница 11: ...e paper is about 20mm out when the printer cover is closed Figure 4b 5 2 Select Display Language To change the display language of the Analyser this can be done while on the wake up screen see fig 5 b...

Страница 12: ...s If you find that LCD screen display is too bright or too dim and need to adjust its contrast then select LCD Brightness from the menu Fig 8 Once entered the display will show as in Fig 9 To increase...

Страница 13: ...n you wish to connect BESA 12P to PC to print or store the results of the last tested vehicle Once the tester is connected to the PC with the USB cable provided select PC Link as in Fig 11 with key an...

Страница 14: ...the menu screens as shown below Fig 13 and Fig 14 EXIT For Example If help is needed on Battery Test then press key on this item and the display will change to as shown Fig 15 Figure 13 Figure 15 Fig...

Страница 15: ...ck to the main menu Fig 5 Let say if you need help on How to operate press key in this selection will get into the display as shown below Figure 16 Figure 17 Battery Test How to operate Voltage Batter...

Страница 16: ...is still in the car Vehicle that was running has to have its engine OFF first and then switch ON the headlights for 30 seconds to remove the surface charge After the headlights had switched OFF let t...

Страница 17: ...you select your choice from the Menu New Clear Memory Selecting this item will allow the tester to clear the last tested results stored in its memory and begin a new test Continue Testing Selecting t...

Страница 18: ...inue Testing will proceed to the display below Fig 23 4 Pressing key once will scroll down to the next item if there is a need to select it 5 As an example Fig 23 the selected item was on Battery Test...

Страница 19: ...the instructions as shown Fig 25 below 8 Wait until the surface charge removal had completed the analyser will advise as follows Fig 26 and then press key Figure 26 Figure 25 Figure 24 The Analyser is...

Страница 20: ...SLI batteries e g normal Flooded types like Wet Low Maintenance Pb Ca Wet Standard Pb Pb Batteries If AGM Flat Spiral is selected then it will test Wet MF Maintenance Free Ca Ca AGM Gel Cell VRLA Ca...

Страница 21: ...les shown below If it is selected under JIS Japanese Industrial Standard then the display will prompt you as shown Fig 29 below Refer to the battery model example 80D26L or NX110 5L on the Cold Cranki...

Страница 22: ...CCA Note WET Wet Cell Type MF Maintenance Free Type SMF Closed or Sealed Maintenance Free 14 To enter the value 630 press key will increase the original value of 500 Fig 31 by step of 100 units to 60...

Страница 23: ...results basing on the evaluation of the tested condition Good indicates the battery in good condition Replace indicates that the battery needs to be replaced If not the battery will fail anytime witho...

Страница 24: ...ion in relation to its rating From the above example a 630 CCA rated battery measuring 406 CCA available power does not mean that the battery would pass a CCA test at 406 CCA The available power readi...

Страница 25: ...ery at 0 F 18 C for 30 seconds while maintaining a voltage of at least 7 2 Volts for a 12V battery during cranking SAE The Society of Automotive Engineers Standard SAE has established Cold Cranking Am...

Страница 26: ...f the results display is shown below Fig 35 To determine the condition of the tested Deep Cycle Batteries refer the Volts reading State of Charge should not fall below 12 60V when fully charged for Le...

Страница 27: ...39 the Results shown To replace this meant that the battery need to be replaced as its internal plate resistance Int R is higher than 15 mOhm 15 Pressing the key at any moment will exit and return bac...

Страница 28: ...N50Z 350 440 525 34B17R 280 60D23R 520 34B17L 280 60D23L 520 34B19R NS40ZA 270 325 400 65D23R 420 540 580 34B19L NS40ZAL 270 325 400 65D23L 420 540 580 34B19RS NS40ZAS 270 325 400 65D26R NS70 415 520...

Страница 29: ...0 20L 1530 1250 8 2 DIN EN Standards Rating Chart Battery Model No Amps Battery Model No Amps DIN EN DIN EN 52805 180 240 55057 320 540 52815 180 240 55068 220 390 53517 175 300 55069 220 390 53520 15...

Страница 30: ...6638 300 510 60026 440 720 56641 300 510 60038 500 760 55647 300 510 60044 500 760 56821 315 540 60527 410 680 56820 315 540 60528 410 680 56828 315 540 61017 400 680 57024 315 540 61018 400 680 57029...

Страница 31: ...Battery Rating Chart 8 4 Rough CCA Guide Given below is a rough CCA ratings guide for any unknown battery model basing on the capacity of the vehicle Vehicle Capacity Approximate Battery CCA Rating 12...

Страница 32: ...rrosion takes place very often If these contacts were no good then it will pose a lot of electrical problems to the vehicle To check the grounding condition this Analyser will measure the resistance f...

Страница 33: ...the Grounding Test Fig 43 5 Press key will proceed to the display as follows Fig 44 Figure 42 Figure 43 Figure 44 Select Test Battery Test Grounding Test Starter Test Alternator Test Then press Enter...

Страница 34: ...you have should unclamp the Black tester clip from the engine or chassis body and transfer to the battery negative terminal within 20 seconds time limit if not the testing procedure has to be repeated...

Страница 35: ...isplay as follows Fig 49 12 If the measured resistance reading has gone beyond the limits then it will display the screen as follows Fig 50 Figure 48 Figure 49 Figure 50 Analysing Please wait Results...

Страница 36: ...ow the right procedures during the testing it will display the results as follows Fig 51 below 14 To exit the program pressing the key at any moment will exit and return back to the main menu screen F...

Страница 37: ...rop which indicates that it is weaker but still usable Whereas Figure C represents a very weak battery that can barely crank a car and is due to fail in the very near future As voltage profiles can in...

Страница 38: ...continue and the display will show Fig 55 3 Switch the ignition key to ON and start cranking the engine until it starts Immediately after that press key and the results will show as follows Figure 55...

Страница 39: ...when it detects that there is no drop in voltage it will display the following screen Figure 58 Figure 56 Figure 57 Figure 58 Result OK Min Volts 10 56V Volt Drop Normal Press Exit to main menu Result...

Страница 40: ...fixed to the case of the alternator and these windings are static i e they don t rotate As the Rotor rotates its magnetic field cuts each Stator winding in turn this induces a current in each winding...

Страница 41: ...harge of the battery controls amperage output of the alternator When the battery has a full charge the electro motive force of the voltage lowers the amperage to almost zero As the battery charge wear...

Страница 42: ...oceed to the display below Fig 61 5 Pressing key to scroll down to the Alternator Test Fig 62 6 Press key to continue and the display will show Fig 63 Figure 61 Figure 62 Figure 60 Select Menu New Cle...

Страница 43: ...w as below Fig 65 With the captured readings analysis can done by referring to the limits as indicated that MAX voltage should not exceed 15 0V max voltage at 3 000 RPM and MIN voltage should be more...

Страница 44: ...to the battery to compensate for the added load This test is to check the alternator s behavior during loading 9 Continue from the previous test either Fig 66 67 or 68 proceed to the next step by pres...

Страница 45: ...out 10 seconds and release the pedal The maximum and minimum voltages values will be captured Fig 70 With the captured readings analysis can done by referring to the limits as indicated that MAX volta...

Страница 46: ...main menu screen Fig 62 12 0 View Last Test Results To view the results of the last test BESA 12P has to be connected to an external power source by either clamping its clips directly to a 12 Volt car...

Страница 47: ...hown Fig 76 3 Pressing key once will scroll down to the View last Test Fig 77 below Figure 75 Figure 76 Figure 77 Select Menu New Clear Memory Continue Testing View last Test Setup Menu Then press Ent...

Страница 48: ...Battery Good Measured 406 CCA Rating 630 CCA Volts 12 45 V Int R 6 72 mOhm Life 76 Results High Ohms The grounding resistance of the engine or car chassis is high Clean the cable contacts or replace...

Страница 49: ...r has to be connected to a 12V battery in order to work with the mobile printer This is because it needs higher Amps to operate which the PC USB output is unable to provide To print just press key on...

Страница 50: ...the proper driver for BESA 12P when connected If you have made the above error and wish to install the driver the second time you need to uninstall the previously installed driver first before starti...

Страница 51: ...prompt you as shown below Click Finish Step 3 Then Plug BESA 12P on any of the USB port and the computer will start to locate the driver and it will pop up a message box as shown below Wait for awhil...

Страница 52: ...by left clicking the and the display page will show as follows Step 6 Now link up BESA 12P with PC through the following procedures 1 On the Main Menu page Fig 83 below select Setup Menu by pressing...

Страница 53: ...ss any other keys because the Analyser is already communicating with the PC 3 To confirm whether there is communication click on Get Data From Analyser tab and the Last Test Result will appear See exa...

Страница 54: ...on this page if you wish to print out the results make sure that your printer is connected to the computer Click on PRINT tab and a text box will appear Select the right printer and click Print tab to...

Страница 55: ...onsequential damages including lost profits in connection with the furnishing performance or use of this material This user manual tells how to use and perform the required procedures on vehicles Safe...

Страница 56: ...ct with extreme heat Cables that have broken bent contact pins or subject to extreme stress or wear Physical damage to the product surface including scratches cracks or other damage to the display scr...