FL-100-5 Dual Fuel Level Indicator
Page 7 of 23
Aerospace Logic Inc.
3150 Ridgeway Drive, Unit #43, Mississauga, Ontario, L5L 5R5, CANADA
Tel. (905) 569-3887 | Fax. (416) 352-5854 | [email protected]
www.aerospacelogic.com
FL-100-5 Operations & Installation Manual – Ver. 2.0 – October 24, 2004
STEP 5
?
Do you want to perform the tank calibration at this point?
•
NO
I just want to return the instrument to normal operations after changing or
viewing the intensity setting for the instrument
o
Then press the switch to the
S
position and release it. Now proceed to
SECTION 4 – Operation.
•
YES
I want to perform the tank calibration for this instrument. I have completed
the installation preparation as outlined in the
FL-100-5 Installation Checklist
and Guide as well as any applicable manufacturer guidelines
.
o
Then move the switch to the
L
position and return it to the
R
position.
STEP 6
The instrument will display either of
these two options depending on the
previous setting.
Now set the sender orientation
From the
FL-100-5 Installation
Checklist
select either
n
or
r
depending on the value in box #
3
OR
If the output voltage from the fuel sending device INCREACES in voltage with fuel
volume select
r
If the output voltage from the fuel sending device DECREACES in voltage with fuel
volume select
n
You can change the setting from
n
to
r
and
r
to
n
by moving the switch to the
L
position and then back to the
R
position. Once the correct value is displayed move the
switch to the
S
position and then back to the
R
position.