FL-100-5 Dual Fuel Level Indicator
Page 12 of 23
Aerospace Logic Inc.
3150 Ridgeway Drive, Unit #43, Mississauga, Ontario, L5L 5R5, CANADA
Tel. (905) 569-3887 | Fax. (416) 352-5854 | [email protected]
www.aerospacelogic.com
FL-100-5 Operations & Installation Manual – Ver. 2.0 – October 24, 2004
STEP 16
?
Do you want to calibrate the RIGHT tank at this time?
•
NO
I want to exit the calibration process.
o
Then move the switch to the
S
position and back to the
R
position. Now
proceed to the STEP 18 of the Setup and Calibration process
•
YES
I want to calibrate the RIGHT tank now. I have completed the installation
preparation as outlined in the
FL-100-5 Installation Checklist and Guide as
well as any applicable manufacturer guidelines
.
o
Then move the switch to the
L
position and then back to the
R
position.
STEP 17
Now perform STEP 8 through STEP 15 for the right tank. The entire process is exactly
the same except that the instrument will display the
r
character instead of the
L
character in the leftmost position of the digital display for all steps.
Once
STEP 15
has been completed for the RIGHT tank proceed to
STEP 18.