Reset generation
10.1
Overview
The reset generator implements input reset signal synchronization with glitch filtering and generates
the internal reset signal. The input reset signal can be asynchronous.
10.2
Signal definitions and reset values
The signals and their reset values are described in table 78.
10.3
Timing
The timing waveforms and timing parameters are shown in figure 32 and are defined in table 79.
Note: The resetn input is re-synchronized internally. The signals does not have to meet any setup or
hold requirements.
Table 78. Signal definitions and reset values
Signal name
Type
Function
Active
Reset value
resetn
Input
Reset
Low
Table 79. Timing parameters
Name
Parameter
Reference edge
Min
Max
Unit
t
RSTGEN
0
asserted period
-
100
-
ns
Figure 32. Timing waveforms
resetn
clk
t
RSTGEN0