AEROFLEX GAISLER
48
RT-SPW-ROUTER
Copyright Aeroflex Gaisler AB
June 2012, Version 1.2
3.7
Registers
The registers listed here are accessed through the RMAP target and the addresses specified shall be set
in the address field of the RMAP command. They can also be accessed through AHB if the AHB slave
is available.
3.7.1
Reset value definitions
3.7.2
Register type definitions
Table 33. Reset value definitions
Value
Description
0
Reset to value 0
1
Reset to value 1
0x0
Hexadecimal value which can be used for multibit fields
NA
Not applicable. For example reserved fields or read only fields which are constant
NR
Not reset
*
Special reset condition. Described in textual description of the bit. Used for example when reset
value is taken from a signal
Table 34. Register type definitions
Value
Description
r
Read only
w
Write only
rw
Readable and writable
wc
Readable and cleared when written with a 1
rc
Readable and cleared when read