![Aeroflex Gaisler RT-SPW-ROUTER Скачать руководство пользователя страница 59](http://html1.mh-extra.com/html/aeroflex-gaisler/rt-spw-router/rt-spw-router_user-manual_2862505059.webp)
AEROFLEX GAISLER
59
RT-SPW-ROUTER
Copyright Aeroflex Gaisler AB
June 2012, Version 1.2
Table 51. Timing parameters - FIFO interface
Name
Parameter
Reference edge
Min
Max
Unit
t
SPWFIFO
0
input to clock setup
rising clk edge
21
-
ns
t
SPWFIFO
1
input from clock hold
rising clk edge
0.5
-
ns
t
SPWFIFO
2
clock to output delay
rising clk edge
4
17
ns
t
SPWFIFO
3
clock to rxchar, timeout output delay
rising clk edge
4
14
ns
t
SPWFIFO
4
clock to output delay
rising clk edge
4
14
ns
t
SPWFIFO
5
txchar, timein input to clock setup
rising clk edge
19
-
ns
t
SPWFIFO
6
txchar, timein input from clock hold
rising clk edge
0.5
-
ns
t
SPWFIFO
7
input to clock setup
rising clk edge
20
-
ns
t
SPWFIFO
8
input from clock hold
rising clk edge
0.5
-
ns
Figure 10. Timing waveforms
- FIFO interface
clk
txchar[], timein[]
(input)
txfull[], txafull[]
t
SPWFIFO7
txwrite[], tickin[]
t
SPWFIFO8
t
SPWFIFO4
clk
t
SPWFIFO5
t
SPWFIFO6
t
SPWFIFO3
t
SPWFIFO0
rxchar[], timeout[]
(output)
rxread[]
t
SPWFIFO2
rxaempty[],
tickout[]
t
SPWFIFO1
rxcharav[],