18
© Aero-Stream, LLC 2022
102822 Rev. H
Installation Process
–
Diffuser(s) and Air Line
1. Locate on the approved plans where the air line will exit the tank (for example, through the side of a
riser, or tank top). As required, drill a 5/8-inch hole. (Figure 22 and Figure 23). Models AS1000-2 and
AS1500-2 with multiple air compressors will require multiple holes.
Figure 22, Air Line Exit
Figure 23, Drill Hole in Riser Side Wall
(Cover & Safety Barrier hidden for clarity)
Assemble Diffuser
2. Remove two-(2) stainless screws from center diffuser section. See Figure 24.
Figure 24, Diffuser Overview
Float Tube
(Top)
Ballast Tube
(Bottom)
Top
Bottom
Diffuser Stone
Screw
Screw