27
© Aero-Stream, LLC 2022
102822 Rev. H
Securing Bio-Brush Ropes
1. Install the safety barrier as instructed in the Riser Installation Guide.
2. Remove the ropes from the temporary tie off and attach all end loops on the ropes through the
carabiner clip. Feed the ropes and carabiner clip through the bottom of the safety barrier. See Figure
434.
Figure 44, Carabiner Clip Connection
3. Install tank lid and secondary plug following processes instructed in the riser installation guide.
Installation of Effluent Filter in Outlet
(If required by local or state code)
1. A filter will require periodic maintenance as outlined by the manufacturer, therefore, plan accordingly
to provide service access.
2. Locate the opening near or above the outlet end of the tank.
3. Install the effluent filter in the outlet tee baffle by sliding the filter into the cavity as shown in Figure 45.
The filter must be in a vertical position as shown. Never install the filter horizontally in the outlet pipe
leading to the dispersion component
Figure 45, Filter Installation into Tee Baffle
Содержание AS1000-2
Страница 8: ...8 Aero Stream LLC 2022 102822 Rev H Figure 4 Picture of the AS450 2 System ...
Страница 9: ...9 Aero Stream LLC 2022 102822 Rev H Figure 5 Picture of the AS500 2 System ...
Страница 10: ...10 Aero Stream LLC 2022 102822 Rev H Figure 6 Picture of the AS600 2 System ...
Страница 11: ...11 Aero Stream LLC 2022 102822 Rev H Figure 7 Picture of the AS750 2 System ...
Страница 12: ...12 Aero Stream LLC 2022 102822 Rev H Figure 8 Picture of the AS1000 2 System ...
Страница 13: ...13 Aero Stream LLC 2022 102822 Rev H Figure 9 Picture of the AS1500 2 System ...