9
IFCLITY1106 - 5773010_01
is a combination of sophisticated
technologies in the field of mechanics
and electronics entirely developed
within the industrial group.
This is a permanent magnet motor with
low starting current and easy speed
adjustment.
Not affected by electromagnetic
interference.
The fact that it is brushless allows lower
friction and less wear.
With the special inverter device, it is
possible to control the speed and torque
of the rotor continuously, just by means
of the stator currents.
The electric motor is cushioned with
elastic supports and the steel shaft is
mounted on
bushings
and resistance
to salt fog is tested in accordance with
ASTM B117/64.
The "brushless electric motor with
Hall sensors" used in AERMEC
FCXI modulating fan coils has huge
advantages over conventional AC motors
and hybrid inverter motors (without
Hall sensor) normally used on other
modulating fan coils:
- reduced wear and tear
- The possibility to regulate the rotation
speed in a precise, continuous manner
(0-100%)
- higher energy yields
- Longer life and greater reliability
- Low magnetic noise
- Continuous monitoring of the rotor
position implies greater efficiency, and
guaranteed and controlled starting
- Guaranteed minimum speed 90 rpm (for
thermodynamic reasons, this limit was
raised to 200 rpm).
CONDENSATE DISCHARGE DEVICE
The condensate discharge device disposes
of the condensate that is produced by
the unit and deposited in the polystyrene
basin. This unit is composed of a control
board, a non return valve, a three level
float and a pump with 800 mm. max.
head. The unit can easily be connected
to the condensate discharge system
by means of a plastic coupling (ext. Ø
16mm).
ALARM: when the level of condensate
in the tray reaches the prefixed limit,
the alarm will stop the flow of water
to the battery, allowing only the fan to
function.
HYDRAULIC CONNECTIONS
The attachment plate groups together
the water connections and the vent of
the coil's primary circuit for 2-pipe and
4-pipe systems. The plates contain raised
symbols that identify the input (IN) and
output (OUT) water connections for the
water.
GLLI10 - GLLI20 (Obligatory accessory)
Intake and delivery grille unit with
electric box
The form and opening of the suction
louvres were developed in order to have
the best possible distribution of the air,
both when functioning in winter as well
as in summer.
Suction occurs through the central grille,
and delivery through the manually
adjustable, perimetric slots.
The plastic, colour RAL 9010, grille
contains the air filter that can be easily
removed for cleaning.
Incorporated electric box with control
board for electrical connections.
The GLLI needs to be interfaced with an
external control panel (not included)
with thermostat and ventilation speed
control, with a 0-10V output.
GLLI10N - GLLI20N (VMF System
obligatory accessory)
Intake and delivery grille unit with
incorporated VMF System-type
thermostat.
To be combined with the VMF-E4 control
panel.
The GLLI_N grille has the same
characteristics as GLLI range grilles.
Incorporated electric box with thermostat
board and connectors for electrical
connections.
For characteristics, see the section on
accessories.
FILTERING SECTION
Mechanical air filter with ABS frame,
colour RAL9010.
Filter in filtering class G1, self-
extinguishing class V0 (UL94).
Easily removable and made from
regenerable materials. May be cleaned
by washing.
SA
SA
SA
SA
SW
SW
VHL
VHL
VHL1
SA
SA
SW
SW
V2
V2
VHL2
SYSTEM EXAMPLE
Key
:
SA
Ambient probe
SW
Water probe
VHL
3-way
valve (Hot/Cold)
V2
2-way valve (Hot/Cold)
VHL1
hot 3-way valve
VHL2
hot 2-way valve
FCLI (Standard)
4-pipe system
2-pipe system
FCLI (V2)
4-pipe system
2-pipe system
FCLI (VL) without valves
4-pipe system
2-pipe system