COOLING CAPACITY - FCLI 42
Tw [°C]
= Inlet water temperature
Ta W.B. [°C]
= Inlet air temperature with wet bulb
Ta D.B.[°C]
= Inlet air temperature with dry bulb
Pc [W]
= Total cooling capacity
Ps [w]
= Sensible cooling capacity
NB: The values in bold type indicate the nominal value.
If sensible power values are above the total cooling capacity, this
means that cooling is carried out without dehumidification.
In this case, only sensible power values are considered.
The cooling outputs of the table are at maximum speed (maximum
air flow).
To determine the cooling capacity based on the speed (air flow),
the values shown in the table must be multiplied by the following
factors (k):
FCLI 42
Qv
[m
3
/h]
k (Pc)
k (Ps)
Speed V4
700
1
1
Speed V3
530
0.82
0.75
Speed V2
360
0.64
0.58
Speed V1
260
0.50
0.44
Tw
[°C]
T [°C]
Ta W.B.
[°C]
Pc [W]
Ps [W]
Pc [W]
Ps [W]
Pc [W]
Ps [W]
Pc [W]
Ps [W]
Pc [W]
Ps [W]
Pc [W]
Ps [W]
21°C Ta D.B.
23°C Ta D.B.
25°C Ta D.B.
27°C Ta D.B.
29°C Ta D.B.
30°C Ta D.B.
5
3
15
3173
2662
3159
3029
3173
3173
3272
3272
3580
3580
3736
3736
17
4094
2648
4086
3022
4078
3391
4069
3758
4057
4057
4061
4061
19
5089
2627
5077
3002
5065
3373
5052
3742
5040
4105
5032
4287
21
6143
2973
6126
3346
6110
3714
6093
4082
6089
4265
23
7270
3308
7262
3685
7237
4051
7229
4235
5
15
2737
2420
2800
2800
2918
2918
3122
3122
3436
3436
3592
3592
17
3711
2441
3703
2813
3691
3180
3707
3556
3748
3748
3790
3790
19
4719
2430
4711
2805
4703
3177
4695
3548
4686
3913
4670
4091
21
5789
2786
5772
3158
5764
3530
5752
3898
5748
4082
23
6932
3131
6916
3502
6900
3871
6891
4055
7
15
2194
2108
2398
2398
2622
2622
2924
2924
3252
3252
3416
3416
17
3156
2152
3150
2523
3201
2911
3303
3303
3439
3439
3529
3529
19
4275
2201
4267
2575
4259
2946
4242
3310
4250
3681
4259
3870
21
5377
2576
5361
2946
5353
3316
5345
3686
5336
3866
23
6538
2931
6529
3305
6513
3674
6505
3857
7
3
15
2463
2273
2497
2497
2633
2633
2947
2947
3258
3258
3411
3411
17
3391
2273
3382
2643
3371
3010
3368
3368
3428
3428
3473
3473
19
4382
2256
4374
2631
4365
3002
4349
3365
4345
3731
4333
3908
21
5435
2607
5419
2977
4349
3365
5394
3712
5390
3895
23
6562
2946
6554
3320
6538
3688
6529
3871
5
15
2033
2025
2211
2211
2469
2469
2794
2794
3114
3114
3269
3269
17
2947
2046
2935
2413
2975
2795
3060
3060
3190
3190
3297
3297
19
3975
2052
3966
2425
3962
2796
3950
3160
3946
3526
3954
3714
21
5048
2414
5040
2787
5032
3156
5015
3520
5011
3702
23
6192
2763
6184
3135
6167
3503
6159
3685
7
15
1584
1584
1906
1906
2251
2251
2593
2593
2924
2924
3088
3088
17
2223
1689
2353
2109
2523
2523
2718
2718
2947
2947
3094
3094
19
3416
1782
3416
2157
3405
2521
3439
2905
3518
3299
3563
3497
21
4579
2189
4571
2560
4563
2927
4555
3293
4555
3477
23
5756
2556
5748
2927
5731
3292
5731
3478
9
3
15
1793
1793
1988
1988
2306
2306
2622
2622
2933
2933
3088
3088
17
2636
1891
2624
2256
2650
2631
2732
2732
2941
2941
3094
3094
19
3633
1886
3625
2258
3617
2625
3606
2988
3597
3351
3603
3537
21
4682
2239
4670
2608
4662
2975
4653
3342
4645
3520
23
5813
2585
5801
2954
5789
3321
5781
3503
5
15
1473
1473
1799
1799
2135
2135
2466
2466
2788
2788
2947
2947
17
2070
1617
2161
2016
2308
2308
2508
2508
2794
2794
2952
2952
19
3162
1664
3156
2033
3150
2401
3167
2775
3230
3159
3275
3275
21
4250
2037
4242
2406
4234
2772
4226
3137
4222
3317
23
5402
2394
5394
2763
5377
3127
5377
3313
7
15
1114
1114
1536
1536
1906
1906
2257
2257
2596
2596
2760
2760
17
1340
1244
1663
1663
1963
1963
2262
2262
2602
2602
2766
2766
19
2409
1325
2426
1699
2523
2101
2670
2519
2845
2845
2941
2941
21
3691
1785
3683
2152
3683
2519
3691
2889
3716
3082
23
4908
2173
4900
2541
4892
2907
4884
3087
COOLING CAPACITY CORRECTION FACTORS