![AEMC instruments 6422 Скачать руководство пользователя страница 36](http://html.mh-extra.com/html/aemc-instruments/6422/6422_user-manual_3049124036.webp)
36
Ground Resistance Testers Models 6422 & 6424
R
H
Ground Electrode Resistance Measurement (Model 6424)
Measurement range
0.050 – 9.999 kΩ
8.00 – 49.99 kΩ
Resolution
1 Ω
10 Ω
Intrinsic uncertainty
± (10 % R + 1 ct)
± (10 % R + 1 ct)
U
SE
Voltage Measurement (Model 6424)
Measurement range
0.10 – 99.99 V
AC/DC
8.00 – 600 V
AC/DC
Resolution
0.01 V
0.1 V
Intrinsic uncertainty
± (2 % R + 2 ct)
± (2 % R + 2 ct)
The instrument is protected up to 600 V between any two of the three input
terminals
3.2.4 Current Measurement (Model 6424)
Additional reference condition:
Peak factor = √2
Measurement
range
0.5 - 999.9 mA
0.800 - 9.999 A
8.00 - 60.00 A
Resolution
0.1 mA
1 mA
10 mA
Intrinsic
uncertainty
± (1 % R + 4 ct)
± (1 % R + 2 ct)
± (1 % R + 2 ct)
3.3 INFLUENCES
3.3.1 Voltage Measurement (Model 6424)
Quantities of
influence
Limits of the range
of use
Variation of the measurement
Typical
Maximum
Temperature
(14 to 122°) F
(-10 to 50) °C
± 0.2 % R
± (0.5 % R + 1 ct)
Relative humidity
(10 to 90) % RH
-
± 2 % R
Frequency
DC to 440 Hz
-
-3 dB
Peak factor
1.4 to 3 (up to 300 V)
-
± 1 % R
DC and 50/60 Hz
common mode
rejection
(0 to 600) V
AC
65 dB
50 dB
Содержание 6422
Страница 1: ...Ground Tester Models 6422 6424 User Manual ENGLISH GROUND RESISTANCE TESTERS WITH AEMC INSTRUMENTS ...
Страница 13: ...Ground Resistance Testers Models 6422 6424 13 1 7 INSTRUMENT INTERFACE 1 7 1 Model 6422 ...
Страница 14: ...14 Ground Resistance Testers Models 6422 6424 1 7 2 Model 6424 ...