13
2.4 Function Test
Move the ON/OFF switch to the discharge position
Turn the temperature selector knob until the fan in the storage heater unit switches on.
If the fan does not switch on, the operating and fault indicators on the charging and discharge
control unit must be observed.
2.5 Transfer
These operating and installation instructions are part of the unit and must be kept in a safe place
by the user. In the case of a change of ownership they must be handed over to the new owner.
The specialist must be given access to the operating and installation instructions for any repair
work.
For the Fitter
•
The separately included wires (double wire and switching wire with distributor) are only needed
in connection with ZH 1004 to ZH 1017. Switch S1 is included with the ZH kits. Please observe
the Instructions for Use and Assembly for Additional Heaters ZH 1004 to 1017.
Tie the wires to the switch in the existing cable harness (cable straps can be opened and
reclosed).
•
Swing back the angle plate and screw tight.
•
Stick the control panel label to the outside of the right side wall.
•
Fix the side wall, front wall and air outlet and inlet grille back to the unit
(in the right order!).
The toothed washers must be inserted under the fastening screws (protective earth
connection!)
•
Plug on the temperature selector knobs.
English