TREK
‐
510
User
manual
56
above
LOW_THRESHOLD,
VPM
controller
will
stop
count
down
and
leave
this
stage.
If
LOW_DELAY
counts
to
zero,
VPM
controller
will
send
an
event
(power
button
press)
to
notify
the
system,
go
into
LOW_
HARD_DELAY
stage
and
start
to
count
down.
Once
LOW_
HARD_DELAY
counts
to
zero,
VPM
controller
will
cut
off
the
system
power
abruptly
to
avoid
draining
out
the
cat
battery.
The
table
below
lists
the
user
programmable
parameters
for
VPM
features:
Default
value
Acceptable
range
ON_DELAY
2
second
1
~
18000
second
OFF_EVENT_DELAY
5
second
1
~
18000
second
HARD_OFF_DELAY
60
second
1
~
18000
second
LOW_THRESHOLD
(12V
mode)
11.42
V
10.09
~
12.25
V
LOW_THRESHOLD
(24V
mode)
22.44
V
21.11
~
23.28
V
LOW_DELAY
30
second
1
~
3600
second
LOW_
HARD_DELAY
60
second
1
~
3600
second
7.3.2
Power
Management
utility
program
Содержание TREK-510
Страница 1: ...TREK 510 User manual 1 User Manual TREK 510 In VehicleComputingBox SmartDisplay User manual...
Страница 10: ...TREK 510 User manual 10...
Страница 17: ...TREK 510 User manual 14 1 3 Dimensions Figure 1 1 TREK 510 dimensions...
Страница 46: ...TREK 510 User manual 46 Figure 6 14 Step 4 Choose setup type Figure 6 15 Figure 6 16...
Страница 47: ...TREK 510 User manual 47 Step 5 Tap Install button to install SDK Figure 6 17 Install SDK...
Страница 50: ...TREK 510 User manual 50 4 Software Hardware reset 5 Get bootloader version 6 Digital I O access...
Страница 60: ...TREK 510 User manual 60 Appendix A C TREK 303 This This appendix explains the TREK 303 detailed information...
Страница 65: ...TREK 510 User manual 65 Appendix B C Windows Embedded CE 5 0 Component List This...
Страница 87: ...TREK 510 User manual 87...