The following table describes the items in the previous figure.
Item
Description
Enable SNTP
Click the radio button to enable or disable the SNTP.
SNTP/NTP Server
Address
Enter the address of the SNTP server. This is a text string of up to 64 characters
containing the encoded unicast IP address or hostname of a SNTP server. Unicast
SNTP requests will be sent to this address. If this address is a DNS hostname,
then that hostname should be resolved into an IP address each time a SNTP
request is sent to it.
SNTP Port
Enter the port on the server to which SNTP requests are to be sent. Allowed
range is 1 to 65535 (default: 123).
Manual Time
Click the drop-down menus to set local date and time of the system.
Time Zone
Click the drop-down menu to select a system time zone.
Daylight Saving Time
Click the drop-down menu to enable or disable the daylight saving time settings.
Daylight Saving Time
Offset
Enter the offsetting variable in seconds to adjust for daylight saving time.
Recurring From
Click the drop-down menu to designate the start date and time for daylight
saving time.
Recurring To
Click the drop-down menu to designate the end date and time for daylight
saving time.
Non-Recurring From
Click the drop-down menu to designate a start date and time for a non-recurring
daylight saving time event.
Non-Recurring To
Click the drop-down menu to designate the end date and time for a non-
recurring daylight saving time event.
Apply
Click
Apply
to save the values and update the screen.
Table 25: System > System Time
Содержание eWorx SE500
Страница 1: ...eWorx SE500 Series Switches User Manual ...
Страница 28: ...eWorx SE500 Series Switches 28 System LED Panel Figure 2 System LED Panel ...
Страница 70: ...eWorx SE500 Series Switches 70 Figure 38 System DHCP Client Option 82 ...
Страница 90: ...eWorx SE500 Series Switches 90 Figure 49 L2 Switching 802 1Q VLAN Port to VLAN ...
Страница 96: ...eWorx SE500 Series Switches 96 Figure 52 L2 Switching GARP GARP Settings ...
Страница 128: ...eWorx SE500 Series Switches 128 Figure 81 Security Storm Control Port Settings ...
Страница 139: ...eWorx SE500 Series Switches 139 Figure 90 Security 802 1x 802 1x Settings ...
Страница 150: ...eWorx SE500 Series Switches 150 Figure 98 QoS General DSCP Mapping ...
Страница 152: ...eWorx SE500 Series Switches 152 Figure 99 QoS General IP Precedence Mapping ...
Страница 159: ...eWorx SE500 Series Switches 159 Figure 106 Management LLDP LLDP System Settings ...
Страница 172: ...eWorx SE500 Series Switches 172 Figure 116 Management Power Over Ethernet PoE Port Settings ...
Страница 188: ...eWorx SE500 Series Switches 188 Figure 128 Management RMON Rmon Alarm ...
Страница 192: ...eWorx SE500 Series Switches 192 Figure 131 Diagnostics Ping Test ...
Страница 205: ...eWorx SE500 Series Switches 205 Figure 140 Tools Upgrade Manager ...