eWorx SE500 Series Switches
:
168
The following table describes the items in the previous figure.
Item
Description
User Name
Enter a user name (up to 32 characters) to create an SNMP profile.
Access Right
Click read-only or read-write to define the access right for the profile.
Encrypted
Click the option to set the encrypted option for the user setting.
Auth-Protocol
Click the drop-down menu to select the authentication level: MD5 or SHA. The
field requires a user password.
MD5: specify HMAC-MD5-96 authentication level
SHA: specify HMAC-SHA authentication protocol
Password
Enter the characters to define the password associated with the authentication
protocol.
Priv-Protocol
Click the drop-down menu to select an authorization protocol: none or DES.The
field requires a user password.
None: no authorization protocol in use
DES: specify 56-bit encryption in use
Password
Enter the characters to define the password associated with the authorization
protocol.
Add
Click Add to save the values and update the screen.
Table 100: Management > SNMP > SNMP User Settings
SNMP Trap
The SNMP Trap page allows you to set the IP address of the node and the SNMP credentials
corresponding to the version that is included in the trap message.
To access this page, click
Management
>
SNMP
>
SNMP Trap
.
Содержание eWorx SE500
Страница 1: ...eWorx SE500 Series Switches User Manual ...
Страница 28: ...eWorx SE500 Series Switches 28 System LED Panel Figure 2 System LED Panel ...
Страница 70: ...eWorx SE500 Series Switches 70 Figure 38 System DHCP Client Option 82 ...
Страница 90: ...eWorx SE500 Series Switches 90 Figure 49 L2 Switching 802 1Q VLAN Port to VLAN ...
Страница 96: ...eWorx SE500 Series Switches 96 Figure 52 L2 Switching GARP GARP Settings ...
Страница 128: ...eWorx SE500 Series Switches 128 Figure 81 Security Storm Control Port Settings ...
Страница 139: ...eWorx SE500 Series Switches 139 Figure 90 Security 802 1x 802 1x Settings ...
Страница 150: ...eWorx SE500 Series Switches 150 Figure 98 QoS General DSCP Mapping ...
Страница 152: ...eWorx SE500 Series Switches 152 Figure 99 QoS General IP Precedence Mapping ...
Страница 159: ...eWorx SE500 Series Switches 159 Figure 106 Management LLDP LLDP System Settings ...
Страница 172: ...eWorx SE500 Series Switches 172 Figure 116 Management Power Over Ethernet PoE Port Settings ...
Страница 188: ...eWorx SE500 Series Switches 188 Figure 128 Management RMON Rmon Alarm ...
Страница 192: ...eWorx SE500 Series Switches 192 Figure 131 Diagnostics Ping Test ...
Страница 205: ...eWorx SE500 Series Switches 205 Figure 140 Tools Upgrade Manager ...