8. MAINTENANCE
This section describes scheduled maintenance procedure for amplifier.
CAUTION
:
Improper maintenance of the amplifier may void the warranty.
8.1 P
REVENTIVE
M
AINTENANCE
This product requires minimum maintenance. This consists of visual inspection and cleaning.
WARNING
:
The person performing maintenance of this equipment must have training and
knowledge of both the product and safety requirements and safety issues related to the
equipment. Read and practice the safety guidelines at the beginning of this manual (
Section
1
at
page 6).
8.1.1 M
ECHANICAL
P
REVENTIVE
M
AINTENANCE
Mechanical preventive maintenance consists of verifying all mechanical parts. Most of them are
performed with the AC power switched off. Perform the following inspection:
1. With the AC power disconnected or switched off, check that all connectors and plugs are
properly seated in their mating connectors and have not been damaged. Replace any bad
connector plugs and reset any that are dislodged.
2. Inspect electrical wiring for signs of discolored, broken or bad insulation. Repair or
replace as needed.
3. Inspects all waveguides for discoloration, cracks, loose connectors and improper sealing.
Tighten or replace waveguides as required.
4. Check for other defects. These include, but are not limited to, wear, fungus, breakage,
deterioration, excess moisture and mounting integrity.
8.1.2 C
HECKING THE
C
OOLING FAN
The cooling fan is located at the back of each unit. Verify that the fan is operating smoothly. Any
suspect noise may indicate wear and fan will have to be replaced. Check for debris or dust in the
fan intake and in all openings on the unit. This may reduce the efficiency of the cooling system.
WARNING
:
Do not come in contact with any electrical assembly while power is on.