AWMA-C250
Page 38
MENU (SCREEN) PAGE #1
NOTE: Commands ‘F5’, ‘F6’, ‘F7’ & ‘F8’ require that the unit to be in REMOTE mode. See
key ‘F2’ bytes 9 & 13 below.
Copyright 1995.
F1
ID
F2
Le
F3
Me
F4
Pa
F5
Re
F6
M
F7
M
f
F8
A
F9
U
F0
Mo
&Ser
ds
ssag
ram
set
UTEon
UTEo
tten
nit#
re
ADVANTECH - Advanced Microwave Technologies, Inc.
Address
: 0
Leds info
: >00AL110010 011 S001 00#K
Message : >00AM#P
Parameters : >00AP A0.0 C112.8 M20.0 O43.1 R17.3 TM49.2 TS28.6
PAGE - 1 - PROTOCOL: ADV, 9600, E Rev 1.40
Alt-X to exit
Figure 9
: Page #1 of the Communication Program
F1 - Queries the unit for ID and serial number.
F2 - Queries the unit for LEDs information. These are the digital outputs of the unit, that
may be used to light LEDs. After disregarding the header, following the ‘L’ the bytes
(‘0’ or ‘1’) represent
1. ‘1’ - The unit is powered. (Will always be ‘1’)
2. ‘1’ - RF output power detected.
3. ‘1’ - Alarm condition exists
4. ‘1’ - Fault condition exists
5. ‘1’ - This unit is connected to the antenna (ON-LINE)
6. ‘1’ - This unit is connected to an RF load (STDBY)
7. ‘1’ - The unit shutdown by operator (MUTE)
8. - No info
9. ‘1’ - unit under remote control / ‘0’- LOCAL control
10. ‘S’