$aaM
Name
Read Module Name
Description
Returns the module name from a specified ADAM-6000 module.
Syntax $aaM(cr)
$
is a delimiter character.
aa
(range 00-FF) represents the 2-character hexadecimal Modbus address
of the ADAM-6000 module you want to interrogate. (Always 01)
M
is the Module Name command.
(cr)
is the terminating character, carriage return (0Dh).
Response !aa60bb(cr)
if the command is valid.
?aa(cr)
if an invalid operation was entered.
There is no response if the module detects a syntax error, communication
error or if the specified address does not exist.
!
delimiter character indicating a valid command was received.
?
delimiter character indicating the command was in-valid.
aa
(range 00-FF) represents the 2-character hexadecimal address of an
ADAM-6000 module.
bb
(range 00-FF) represents the 2-character model number of an
ADAM-6000 module.
(cr)
is the terminating character, carriage return (0Dh).
Example
command:
$01M(cr)
response:
!0150(cr)
The command requests the system at address 01h to send its module name.
The system at address 01h responds with module name
6050
indicating that
there is an ADAM-6050 at address 01h.
Содержание ADAM-6000 series
Страница 21: ...Figure 3 2 Fix ADAM 6000 module on the bracket...
Страница 23: ......
Страница 24: ...Figure 3 4 Secure ADAM 6000 Module to a DIN rail...
Страница 27: ...Figure 3 6 ADAM 6000 I O Module Terminal Block wiring...
Страница 32: ...Figure 4 4 ADAM 6017 Digital Output wiring...
Страница 36: ...Figure 4 8 ADAM 6050 Digital Output Wiring...
Страница 41: ...Figure 4 13 ADAM 6051 Digital Output and Counter Wiring...
Страница 46: ...Figure 4 18 ADAM 6060 Relay Output Wiring...
Страница 75: ...Figure 5 29 Firmware Upgrade for ADAM 6000 I O Series Modules...
Страница 153: ...Appendix A Design Worksheets...