background image

1-10 

Wi232/WiUSB User Guide 

 

 

1.10 Technical Specifications

 

Table 4 - Technical Specs

 

 

Category

 

Description

 

CPU 

DSTni-EX 186 CPU, 256 KB zero wait state SRAM 
2048KB Flash, 16KB Boot ROM 

Firmware 

Upgradeable via TFTP and serial port 

Reset Circuit 

Reset In is low active. (Software reset only) 

Serial Interface 

RS232. Baudrate software selectable (300 to 921600) 

USB 

USB Type A Male connector. USB Specification 2.0 Compliant, Full Speed (12Mbps). 
Baud rates: 300bps to 921.6Kbps. 
512 Byte Receive Buffer, 512 Byte Transmit Buffer. 
Virtual COM Port Device Drivers for Win 98/2000/XP, Win CE, Linux 2.40 

Serial Line Formats 

7 or 8 data bits,  1-2 Stop bits, Parity: odd, even, none 

Flow Control 

XON/XOFF (software), CTS/RTS (hardware), None 

Network Interface 

Wireless 802.11b, 802.11g and 10/100 Ethernet 

Compatibility 

Ethernet: Version 2.0/IEEE 802.3 

Protocols Supported 

ARP, UDP, TCP, Telnet, ICMP, SNMP, DHCP, BOOTP, Auto IP, TFTP,  SMTP, and 
HTTP, CSMA/CA with ACK 

Data Rates With 
Automatic Fallback 

54Mbps 

— 1Mbps 

Medial Access Control 

CSMA/CA with ACK 

Distance 

Up to 328 feet indoors 

Modulation 

OFDM, DSSS, CCK, DQPSK, DBPSK, 64 QAM, 16 QAM 

Transmitter 

2.412 

– 2.484 GHz, 14dBm +1.5 dBm/-1.0 dBm 

Receive Level 

-10dBm (with PER < 8%) 

Average Power 
Consumption 

WiPort-G 1300 mW (WLAN mode;maximum data rate) 

300 mW (WLAN mode;idle) 
750 mW (Ethernet mode) 

Wi232 Module: 150ma @12VDC 

Power Input 

9VDC to 24VDC. 
9VDC, 500 mA, 8W External Adapter Included.  120VAC (USA) or 100-240VAC 
Universal with adapters. 

LEDs 

RJ45 Jack: GRN: Ethernet Act, YEL: Link. 
Case: GRN: Power, GRN: WLAN Activity 

Management 

Internal web server, Device Installer Software, Serial login, Telnet login 

Security

 

Password protection, Locking features, 64/128 bit WEP, WPA, 802.11i/WPA2

 

Internal Web Server 

Serves static web pages and Java applets. Storage capacity: 1.2MB or 19 pages of 64K 
each. Extended range WiPort has 51 pages of 64K per page. 

Dimensions 

2.42”w x 3.80”h x 1.025”d  (See the wi232_wall_plate.pdf drawing on the CD) 

Weight 

5.4oz (with antenna) 

Material 

Case: Flame Retardant 

Temperature 

Operating range: -40°C to +70°C, Storage range: -40°C to +85°C (-40°F to 185°F) 

Relative Humidity 

Operating: 5% to 95% non-condensing 

Warranty 

1-year limited warranty 

Included Software 

Windows™ 98/NT/2000/XP based Device Installer configuration software, Windows™ 
based Comm Port Redirector and USB device drivers. 

EMI Compliance 

Radiated & conducted emissions - complies with Class B limits of EN 55022:1998 
Direct & Indirect ESD - complies with EN55024:1998 
RF Electromagnetic Field Immunity - complies with EN55024:1998 
Power Frequency Magnetic Field Immunity - complies with EN55024:1998 

Содержание Wi232

Страница 1: ...SB Serial to Wireless Ethernet Adapter Revision E January 2008 Document Part Number GC 800 300 Advantage Lab GmbH www advantage devices com Otto Röhm Strasse 69 info advantage lab com 64293 Darmstadt Germany v1 ...

Страница 2: ...or in other applications intended to support or sustain life or in any other application in which the failure of a Advantage devices product could create a situation where personal injury death or severe property or environmental damage may occur Advantage devices reserves the right to discontinue or make changes to its products at any time without notice Advantage devices and the Advantage device...

Страница 3: ...uipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with this guide may cause harmful interference to radio communications Changes or modifications to this device not explicitly approved by Advantage devices will void the user s authority to operate this device The information in this guide may change without notice The manufacturer assumes no ...

Страница 4: ......

Страница 5: ...e will operate substantially for a period of 60 DAYS after the date of shipment In no event will Advantage devices be responsible to the user in contract in tort including negligence strict liability or otherwise for any special indirect incidental or consequential damage or loss of equipment plant or power system cost of capital loss of profits or revenues cost of replacement power additional exp...

Страница 6: ...ringtheWi232forWAP 2 2 2 2 1 Wi232Configuration WAP 2 2 2 2 2 WirelessAccessPoint WAP Connection 2 4 2 3 InstallingandConfiguringforaWirelessRouter 2 7 2 3 1 Wi232Configuration Router 2 7 2 3 2 NetworkConfiguration 2 8 2 4 Quick Test 2 11 3 Configuration Using Web Manager 3 1 3 1 Network Configuration 3 2 3 1 1 Network Mode 3 2 3 1 2 AutomaticIPAddressConfiguration 3 2 3 1 3 StaticIPAddressConfigu...

Страница 7: ...2 15 Channel Port Password 4 15 4 3 E mail 4 15 4 4 WLAN Settings 4 15 4 5 Expert Settings 4 17 4 6 Security Settings 4 18 4 6 1 Disable SNMP 4 18 4 6 2 SNMPCommunityName 4 18 4 6 3 DisableTelnetSetup 4 18 4 6 4 DisableTFTPFirmwareUpgrade 4 19 4 6 5 DisablePort77FE Hex 4 19 4 6 6 DisableWebServer 4 19 4 6 7 DisableWebSetup 4 19 4 6 8 DisableECHOPorts 4 19 4 6 9 EnableEncryption 4 19 4 6 10 EnableE...

Страница 8: ... of Figures Figure 1 Serial Tunneling Example 1 3 Figure 2 Ad Hoc Network Example 1 3 Figure 3 Serial Tunneling Infrastructure 1 4 Figure 4 Direct Wi232 to Wi232 Connection 1 4 Figure 5 Wi232 Connection 2 2 List of Tables Table 1 RS232 Signals 1 5 Table 2 USB Signals 1 6 Table 3 OEM Header Wiring 1 8 Table 3 Technical Specs 1 10 ...

Страница 9: ...o customize the user interface by employing common and familiar tools the Wi232 serves applets to a Web browser resulting in interactive Web pages This customization of HTML Web pages and configuration screens tailors the Wi232 to fit unique requirements The Wi232 device server has the following capabilities Communication between TCP and UDP to serial Wireless interface 802 11b or Ethernet interfa...

Страница 10: ...st QuickStart_800234_x pdf Comm Port Redirector Guide Provides information on using the Windows based utility to create a virtual com port Redirector_UG_800235_x pdf Web Enable User Guide Explains the steps to get your device Web enabled Web_Enabling_UG_800236_x pdf GPIO Interface Guide Introduction to the GPIO interface and a demo program GPIO_800237_x pdf UDP Configuration Guide How to use UDP t...

Страница 11: ...neling Example Ethernet Personal Computer PC Wireless Laptop Wi232 POS Device A PC connected to an Access Point via an Ethernet connection and a laptop with a wireless connection to the Access Point LAN access the Wi232 as though they are directly connected to it The combination of the Wi232 a PC and Redirector software allows the PC to directly communicate to the Wi232 s serial devices providing ...

Страница 12: ...to peer relationship They communicate directly to each other s serial devices without a PC or an Access Point Note How do you set up the units for point to point See Application Note Wi232 Serial Tunnel GC 800 302 1 3 Protocol Support The Wi232 uses the Internet Protocol IP for network communications and the Transmission Control Protocol TCP to assure that no data is lost or duplicated and that ev...

Страница 13: ...ignals Wi232 Signal Direction DTE DB 9 Male Pin DCE DB 9 Female Pin Data Out TXD Out 3 2 Data In RXD In 2 3 Ground 5 5 RTS In 8 7 CTS Out 7 8 DTR Use J5 to jumper 4 6 4 6 DSR Use J5 to jumper 4 6 6 4 Note J5 is used to jumper cable pins 4 to 6 which ties DTR to DSR To locate J5 open the case by removing the two screws Use the drawing below to locate the jumper J5 J5 is used to tie DSR to DTR Used ...

Страница 14: ...r source from 9VDC to 24VDC A typical power cube sent with the unit is a 9VDC 500 mA 8W power cube However there are other units that can be used as long as they are in the range of 9 24VDC and supply the proper wattage The Wi232 power adapter is a 2 1mm positive center power jack The jack is equivalent to a CUI Inc PJ 002A power jack You can also order the Wi232 with a Phoenix right angle power c...

Страница 15: ...e Wi232 as an OEM board you can mount the board to your device and connect the signal wires using the following drawings 1 8 1 Mounting Holes The following drawing shows the mounting holes for the Wi232 OEM board If the power jack is removed one of the holes can be used for mounting the board 125mil 3 175mm 130mil 3 302mm Can be used if the power jack is not installed 125mil 3 175mm ...

Страница 16: ...9 1050 Digi Key WM18652 ND Part for Wi232 Connector Receptacle 10 Pos 2mm Vert PC Board Mfg 79107 7004 Digi Key WM18676 ND Circuit Board Part BOTTOM LAYER The pads are wired according to the following table Table 3 OEM Header Wiring Pin Description 1 Ground 2 Ground 3 CTS Out 4 Ground 5 RTS In 6 Ground 7 TXD Out 8 V In 9 RXD In 10 V In 1 8 3 Board Dimensions The dimensions for the mounting holes a...

Страница 17: ...t CD The product CD sent with the Wi232 WIUSB contains Device Installer software ComPort Redirector SetZone Utility USB Device Drivers Application Notes and technical documents The CD contains Virtual COM Port Drivers for the NETUSB device ...

Страница 18: ...8 Average Power Consumption WiPort G 1300 mW WLAN mode maximum data rate 300 mW WLAN mode idle 750 mW Ethernet mode Wi232 Module 150ma 12VDC Power Input 9VDC to 24VDC 9VDC 500 mA 8W External Adapter Included 120VAC USA or 100 240VAC Universal with adapters LEDs RJ45 Jack GRN Ethernet Act YEL Link Case GRN Power GRN WLAN Activity Management Internal web server Device Installer Software Serial login...

Страница 19: ... IP address and corresponding subnet mask and gateway If you leave the IP address set to 0 0 0 0 the Wi232 will attempt to get a DHCP address from the wireless Access Point or network server If it cannot get a DHCP address it will use AutoIP to assign an IP address Before the Wi232 can communicate on an 802 11b wireless network the WLAN settings must match the wireless network By default the Wi232...

Страница 20: ...ion e g HyperTerminal The default serial settings are 9600 baud 8 bits not parity 1 stop bit and no flow control 9600 8 N 1 Note The default settings are always the same for the first 5 seconds of startup 4 EnterSetupModebyconnectingthepowersupplyandholdingdownthelowercasex key validfor5 seconds 5 Uponconnection thefollowinginformationdisplays MAC address 00204A8245A8 Software version V6 3 0 0 060...

Страница 21: ... d Netmask a netmask defines the number of bits taken from the IP address that are assigned for the host part Netmask Number of Bits for Host Part 0 default 8 e Change Telnet Configuration Password change the Telnet configuration password to prevent unauthorized access to the Setup Menu Change telnet config password N f Change DHCP device name Change DHCP device name not set N 7 ToconfiguretheWLAN...

Страница 22: ...tosavethesetup parametersandexittheWi232SerialModesetup Parameters stored 9 TheWi232isreadyforwirelessconnection 2 2 2 Wireless Access Point WAP Connection In the following example a Wireless Access Point was assigned the network name of ADVANTAGE DEVICES Verify your wireless adapter is inserted correctly in the PC or laptop Ensure the wireless adapter s drivers and utilities are installed Go to S...

Страница 23: ... 2 5 In the following example an Orinoco wireless adapter is used Select Internet Protocol TCP IP from the list Click the Properties button Set the adapter to obtain an IP address automatically from the Wireless Access Point ...

Страница 24: ...ify the unit can send and receive data between the serial port and the Ethernet port Continue with Configuration Using Web Manager on page 3 1 If you did NOT assign an IP address and allowed the unit to acquire a DHCP or AutoIP address then you will need to locate the unit on the network and determine the IP address The best way to locate the unit is with the Device Installer utility included on t...

Страница 25: ...address set to 192 168 2 101 IP Address 000 192 Enter 000 168 Enter 000 2 Enter 000 101 Enter c Set Gateway IP Address the gateway address should be the IP address of the router connected to the same LAN segment as the Wi232 unit If there is no router press Enter to accept the default The example shows the gateway set to 192 168 2 1 Set Gateway IP Address N Y Gateway IP addr 000 192 Enter 000 168 ...

Страница 26: ...er management N _ 3 UponcompletingtheIPandWLANsettingsconfiguration type9 atthepromptandpressEntertosavethesetup parametersandexittheWi232SerialModesetup Parameters stored 4 TheWi232isreadyforwirelessconnection 2 3 2 Network Configuration Verify your wireless adapter is inserted correctly in the PC or laptop Ensure the wireless adapter s drivers and utilities are installed Go to Start Settings Net...

Страница 27: ...lect Internet Protocol TCP IP from the list Click the Properties button Set the adapter to an address compatible with your router In the example below the router base address is 192 168 2 xxx In the following dialog box the IP subnet and gateway addresses match the base address of the router ...

Страница 28: ...nnel Verify that the wireless adapter is connected to the router and has a good signal At this point you should be able to access the Wi232 through a wireless connection Note Try the Quick Test in the next section to verify the unit can send and receive data between the serial port and the Ethernet port You can continue to configure the device by going to Configuration Using Web Manager on page 3 ...

Страница 29: ... Ethernet port to the serial port Serial Session Start a session of HyperTerminal or other terminal emulation program Enter a name for the new connection and click OK Example SERIAL In the Connect To dialog box go to the Connect using field and select the serial Com port that is connected to the Wi232 and click OK In the COMx Properties dialog box enter 9600 8 None 1 None and click OK This is the ...

Страница 30: ...number Click OK This is the Ethernet terminal The status message for the TCP IP connection should show it is connected Resize the two HyperTerminal windows so you can see both on your screen Select one of the Hyper Terminal screens and begin to type characters The typed characters should appear in the other Hyper Terminal window You may have to go back and forth between the screens for the charact...

Страница 31: ...pening a web browser or by clicking on the Web icon in Device Installer software For more information about using Device Installer see the Device Installer user manual Note PLEASE read the readme txt notes in the Device Installer folder before installing the software Note This section contains minimum descriptions of the selections available in the menus See the section for Telnet or Serial Mode f...

Страница 32: ...on 1 Click Network from the main menu 2 Select Obtain IP address automatically 3 Enter the following as necessary BOOTP Select Enable to permit the Bootstrap Protocol BOOTP The BOOTP server automatically assigns the IP address from a pool of addresses DHCP Select Enable to permit Dynamic Host Configuration Protocol DHCP DHCP automatically assigns a leased IP address to the Wi232 unit Auto IP The W...

Страница 33: ...way address should be the IP address of the router connected to the same LAN segment as the unit The gateway address must be within the local network 4 Click the OK button when finished 3 1 4 Ethernet Configuration You must specify the speed and direction of data transmission To specify how data will be transmitted 1 On the main menu click Network 2 Enter the following as necessary Auto Negotiate ...

Страница 34: ...ve connection before checking its status If the unit does not receive a response it drops that connection Enter a value between 0 and 60 seconds 0 disables keepalive Monitor Mode Bootup Select Disable to disable the entry into the monitor mode via the yyy or xx1 key sequence at startup This command prevents the unit from entering monitor mode by interpreting the stream of characters that are recei...

Страница 35: ...he unit stops trying to connectto anyothers Ifthisconnectionfails the unit continues to scroll through the table until the next successful connection The hostlist supports a minimum of 1 and a maximum of 12 entries Each entry contains an IP address and a port number Note The hostlist is disabled for Manual and Modem Mode The unit will not accept a data connection from a remote device when the host...

Страница 36: ...2 is NOT available on Wi232 Port Settings Protocol Select the protocol type from the pull down menu for the selected channel The only option for Wi232 is RS232 Flow Control Flow control manages data flow between devices in a network to ensure it is processed efficiently Too much data arriving before a device is prepared to manage it causes lost or retransmitted data Select CTS RTS for hardware flo...

Страница 37: ...ly to indicate to the Wi232 end of the data collection Match Bytes Use to indicate the end of a series of data to be sent as one group Set this value to 00 if specific functions are not needed Send Frame Only After the detection of the byte sequence indicates whether to send the data frame or the entire buffer Select True to send only the data frame Send Trailing Bytes Select the number of bytes t...

Страница 38: ...on Connect Protocol Protocol Select TCP from the pull down menu Connect Mode Passive Connection Accept Incoming Select Yes to accept incoming connections Do not select With Active Mdm Ctrl In This is a configurable pin that is not used Password Required Determines whether a password is required for an incoming passive connection Field is not available when a password is set for Telnet mode Passwor...

Страница 39: ...mmand with a single character response Modem Esc Seq Pass Thru Set to Yes to pass Modem Escape Sequence Endpoint Configuration Local Port Enter the local port number Auto increment for active connect Select auto increment for new outgoing connections The range of auto incremented port numbers is 50 000 to 59 999 and loops back to the beginning when the maximum range is reached Remote Port Enter th...

Страница 40: ... 04 is detected Both Telnet mode and Disconnect with EOT must be enabled for Disconnect with EOT to function properly Ctrl D is only detected going from the serial port to the network Inactivity Timeout Use this parameter to set an inactivity timeout The unit drops the connection if there is no activity on the serial line before the set time expires Enter time in the format mm ss where m is the nu...

Страница 41: ... FD option Accept Incoming Select Yes to accept incoming UDP datagrams Can also select With_Active_Mdm_Ctrl_In Endpoint Configuration Local Port Enter the local port number Remote Port Enter the port number of the remote device Remote Host Enter the IP address of the remote device Device Address Table Field enabled when Datagram Type is set to FD Enter values between 1 255 to identify units on the...

Страница 42: ...32 WLAN Settings menu permits the following actions Configuration of the wireless network profile available for activation Configurationofthewirelessnetworksecuritysettings Configuration of advanced settings such as radio power management Forconnectingto wirelessnetworks theconfigurationof a name for the network with which the Wi232 wants to associate is done with the Network Name SSID field The W...

Страница 43: ...e and support any number of wireless clients Ad Hoc mode An 802 11 networking framework in which devices or stations communicate directly with each other without the use of an access point AP Ad hoc mode is also referred to as peer to peer mode or an Independent Basic Service Set IBSS Ad hoc mode is useful for establishing a network where wireless infrastructure does not exist or where services ar...

Страница 44: ...for both 802 11i and WPA2 Authentication Select an authentication scheme from the pull down menu Open None or Shared for WEP Selecting Shared requires manually entering the authentication key Pre Shared Keys for WPA and 802 11 WPA2 Encryption Select the encryption type from the pull down menu For WEP select 64 or 128 bits 64 bits is the default encryption For WPA select TKIP or TKIP WEP For 802 11...

Страница 45: ...ration is saved The unit will reboot when done 3 9 Apply Factory Defaults Click the Apply Factory Defaults button to restore theWi232 s factorydefaults A confirmation window displays requesting confirmation on restoring the Wi232 s default settings Click YES to apply the factory settings ...

Страница 46: ...i232 unit by cycling the unit s power turning the power off and back on Immediately upon resetting the device enter three lowercase x characters xxx Note The easiest way to enter the Serial Mode s Setup menu is to hold down the x key at the terminal or emulation while resetting the unit This must be done within 5 seconds of resetting the Wi232 3 Upon connection the following information displays M...

Страница 47: ...t as the unit The gateway address must be within the local network The default is N No indicating the gateway address has not been set To set the gateway address type Y At the prompt enter the gateway address Set Gateway IP Address N Y Gateway IP addr 0 0 0 0 _ Set the Netmask A netmask defines the number of bits taken from the IP address that are assigned for the host part Netmask Number of Bits ...

Страница 48: ......

Страница 49: ...is the last octet of the IP address If the IP address specified is 0 0 0 12 thentheDHCPnameisLTX12 Thismethodonlyworkswith 2 digit numbers 0 99 4 2 Channel 1 Configuration Select option 1 Channel 1 from the Change Setup menu to define how the serial port responds to network and serial communications The following sectionsdescribetheconfigurableparameterswithin the Channel configuration menu Note T...

Страница 50: ... 1 1 7 Bit 1 0 8 Bit 1 1 No Parity 0 0 Even Parity 1 1 Odd Parity 0 1 1 stop bit 0 1 2 stop bits 1 1 1 1 2 stop bits are implemented by the software This might influence performance The following table demonstrates some common I F Mode settings Common I F Mode Setting Binary Hex RS 232C 8 bit No Parity 1 stop bit 0100 1100 4C RS 232C 7 bit Even Parity 1 stop bit 0111 1000 78 4 2 3 Flow Flow contro...

Страница 51: ...rentheses The default setting for Port 1 is 10001 The range is 1 65535 except for the following reserved port numbers Port Numbers Reserved for 1 1024 Reserved 9999 Telnet setup 14000 14009 Reserved for Redirector 30718 Reserved 77FEh Note Do NOT use the reserved port numbers for this setting as incorrect operation may result Use Port 1 for the outgoing local port to change with each connection Th...

Страница 52: ...onnection 0 1 0 0 Autostart 0 1 0 1 Hostlist 0 0 1 0 d Datagram Type Directed UDP 1 1 0 0 e Modem Mode Full Verbose 1 0 1 1 0 Without Echo 0 0 1 1 0 Numeric modem result codes 1 0 1 1 1 Incoming Connection Never Accept Incoming Rejects all external connection attempts Accept with modem_control_in Active Accepts external connection requests only when the modem_control_in input is asserted Cannot be...

Страница 53: ...tion port number The IP address must be in standard dot decimal notation and may be a partial address representing the least significant 1 2 or 3 bytes of the remote IP address The period is required between each octet of IP address numbers If present the port number must follow the IP address must be presented as a decimal number in the range 1 65535 and must be preceded by a forward slash ASCII ...

Страница 54: ...e device server scrolls through the hostlist until it connects to the first available device listed in the hostlist table Once it connects the unit stops further attempts If this connection fails the unit continues to scroll through the table until it is able to connect to the next available IP address in the hostlist Hostlist supports a minimum of 1 and a maximum of 12 entries Each entry contains...

Страница 55: ... commands and handles the modem signals correctly Normally there is a modem connected to a local PC and a modem connected to a remote machine A user must dial from the local PC to the remote machine accumulating phone charges for each connection Modem Mode allows you to replace modems with Wi232es and to use an Ethernet connection instead of a phonecall Bynot havingtochangecommunicationsapplicatio...

Страница 56: ...aracterResponseoptionisineffect the unit responds to an unrecognized command string that is otherwise formatted correctly with OK and takes no further action When an active connection is in effect the unit transfers data and does not process commands received from the serial interface When a connection is terminated or lost the unit reverts to command mode When an active connection is in effect th...

Страница 57: ...TEn Enables or disables character echo and responses n 0 disables character echo and responses n 1 enables character echo and responses ATVn Enables 1 character response or full verbose n 0 enables 1 character response n 1 enables full verbose Note The unit recognizes these AT commands as single commands such as ATE0 or ATV1 it does not recognize compound commands such as ATE0V1 4 2 6 Send the Esc...

Страница 58: ...de Options Disconnect Mode Option 7 6 5 4 3 2 1 0 Disconnect with modem_control_in drop 6 1 Ignore modem_control_in 0 Telnet Terminal type 1 1 Channel port password 2 1 Hard disconnect 3 0 Disable hard disconnect 1 State LED off with connection 4 1 Disconnect with EOT D 5 1 1 The Wi232 sends the Terminal Type upon an outgoing connection Not used with password option 2 A password is required for a ...

Страница 59: ... 4 3 2 1 0 Input Buffer Serial to Network Clear with a connection that is initiated from the device to the network 1 Clear with a connection initiated from the network to the device 1 Clear when the network connection to or from the device is disconnected 1 Output Buffer Network to Serial Clear with a connection that is initiated from the device to the network 1 Clear with a connection initiated f...

Страница 60: ... interval is 12 ms Trailing Characters In some applications CRC Checksum or other trailing characters follow the end of sequence character this option helps to adapt frame transmission to the frame boundary Send Characters If 2 Byte Send Character Sequence is enabled the unit interprets the sendchars as a 2 byte sequence if this option is not enabled the unit interprets them independently IfSendIm...

Страница 61: ...on is enabled set a password on the serial port 4 3 E mail The Wi232 does not utilize this feature at this time You can make it work by looking for characters on the serial port However we do not recommend this operation 4 4 WLAN Settings A wireless LAN is susceptible to access by unauthorized users As such Wi232 includes the Wired Equivalent Privacy WEP encryption standard Wi Fi Protected Access ...

Страница 62: ...oint to another Select 64 or 128 bit encryption WPA offers TKIP or TKIP WEP 802 11i WPA2 offers CCMP CCMP TKIP CCMP WEP TKIP TKIP WEP The WEP options are shown below Encryption 1 WEP64 2 WEP128 1 Display Current Key Displays when Security is set to 1 WEP or 2 WPA Selecting Y will display the current key on the following line Display current key N Change Key Displays when Security is set to 1 WEP o...

Страница 63: ...che Timeout When the unit communicates with another device on the network it adds an entry into its ARP table ARP Cache timeout defines the number of seconds 1 600 the unit waits before timing out this table ARP Cache timeout in s 1s 600s 0s disable 600 CPU Performance The standard CPU performance mode supports up to 230400 baud Select 1 Low for low power Select 2 High to increase the CPU performa...

Страница 64: ... serial connections not on the Web Manager Note As recommended set security over the dedicated network or over the serial setup If the parameters are set over the network Telnet 9999 someone else could capture these settings Caution Disabling both Telnet Setup and Port 77FE prevent users from accessing the setup menu from the network 4 6 1 Disable SNMP For security purposes disable SNMP if require...

Страница 65: ... disables the web server This setting defaults to the N No option Disabling the web server also disables the web setup Disable Web Server N _ 4 6 7 Disable Web Setup The Y Yes option disables configuration via the Web Manager but the web server remains active for custom web pages This setting defaults to the N No option Disable Web Setup N _ 4 6 8 Disable ECHO Ports This setting controls whether t...

Страница 66: ...ttings that this option changes are listed below Channel 1 Configuration Baudrate 9600 I F Mode 4C 1 stop bit no parity 8 bit RS 232C Flow 00 Port No 10001 Connect Mode C0 always accept incoming connection no active connection startup Auto Increment source port N Remote IP Address 0 0 0 0 Remote Port 0 DisConnMode 00 FlushMode 00 DisConnTime 00 00 Send Character 1 00 Send Character 2 00 Expert Set...

Страница 67: ...etup N No Disable ECHO ports Y Yes Enable Enhanced password N No Disable Port 77F0h N 4 7 1 Exit Configuration Mode To exit setup mode Select option 9 Save and exit from the Change Setup menu to save all changes and reboot the device All values are stored in nonvolatile memory or Select option 8 Exit without save from the Change Setup menu to exit the configuration mode without saving any changes ...

Страница 68: ...ss 00204A0113A3 Software version Press Enter to go into Setup Mode 2 Type M upper case The following prompt appears NodeSet 2 0 0 A 0 prompt indicates that you have successfully entered Monitor Mode 5 1 3 Monitor Mode Commands The following commands are available in Monitor Mode Note All commands must be in capital letters Command Command Name Function VS Version Queries software header record 16 ...

Страница 69: ... memory page of configuration information on the device Responses to some of the commands are given in Intel Hex format Note Entering any of the commands listed above generates one of the following command response codes Command Response Codes Response Meaning 0 OK no error 1 No answer from remote device 2 Cannot reach remote device or no answer 8 Wrong parameter s 9 Invalid command ...

Страница 70: ...res This should only be done under the direction of technical support Units with firmware other than that originally intended for the product are not supported 6 1 2 Via Device Installer After copying the firmware to your computer use Device Installer to install it 1 Store the firmware in a subfolder on your computer 2 Start Device Installer and search the network for the device you want to upgrad...

Страница 71: ...e AP Enable WEP encryption in Wi232 Set encryption key and authentication type to match the AP Ensure the key is entered in HEX notation in both the AP and the Wi232 Cannot establish an Ad Hoc network connection to the Wi232 Ad Hoc network is not enabled in the Wi232 Enable Ad Hoc network Set Ad Hoc Network Name IBSS to match These are case sensitive Infrastructure Network Name SSID is set blank o...

Страница 72: ...rs A F In Windows and usually in Unix the segments of the Ethernet address are separated by dashes In some forms of Unix the Ethernet address is segmented with colons The IP address you are trying to assign is not on your logical subnet Confirm that your PC has an IP address and that it is in the same logical subnet that you are trying to assign to the device server The device server may not have ...

Страница 73: ...sponse then there is a duplicate IP address on the network If you do not get a response use the serial port to verify that Telnet is not disabled If you are experiencing an error that is not described in this chapter or if you are unable to fıx the error you may check the online knowledge base for the WiPort at www lantronix com support Firmware downloads and FAQs are available at www lantronix co...

Страница 74: ... numbers to hexadecimals 8 1 1 Conversion Table Hexadecimal digits have values ranging from 0 to F which are represented as 09 A for 10 B for 11 etc To convert a binary value for example 0100 1100 to a hexadecimal representation the upper and lower four bits are treated separately resultingina two digithexadecimalnumber in this case 4C Use the following table to convert values from binary to hexad...

Страница 75: ...a scientific calculator such as the one available on Windows operating systems For example 1 On the Windows Start menu click Programs Accessories Calculator 2 On the View menu select Scientific The scientific calculator displays 3 Click Bin Binary and type the number to convert Click Hex The hexadecimal value displays ...

Отзывы: