The Advanced Visual Solutions AV102 series of intercoms use this unit as both a power
supply source and an audio interface. These intercoms have their push-buttons isolated
from the cables by means of an internal opto-isolator device.
It is most important
to maintain the correct polarity of the cables between the AV102 and
the AVPSU4 units.
The AV102 is factory wired to be a normally closed device when it is powered-up and the
push-button is not pressed.
The LED on the AVPSU4 illuminates when the call input terminals are open-circuit. This
function may be used to check that the call button is wired and functioning correctly.
AVPSU4 PARTS IDENTIFICATION DRAWING
7
6
5
4
3
2
1
1
DC power output to AV102SS
intercom unit
2
Power on LED
3
Call Output : Clean contact output
changes when push-button is
being pressed
4
Terminals for wiring to and from
AV102SS intercom unit
5
Connect LED : Lights when
system connected to a (powered)
ADPRO Fast-Scan transmitter.
6
Call Out LED. Changes state
when call button pressed.
7
15 Pin D connector : For direct
connection to an ADPRO remote
video/audio transmitter.
8
Audio Input (from transmission
equipment)
9
Audio Output (to transmission
equipment)
10
Alternative Audio Input and
Output (to and from transmission
equipment)
11
Call Output Select : Sets call
output to normally open or
normally closed
12
24 Volt DC input (use supplied,
regulated adapter only)
12
11
10
9
8
DOCUMENT NUMBER AV102SS/OEM/01 REVISION 6.1 1st August 2006 Page
19