Page 9
Modulating Unitary Range
VA-LT206_11292016al
Reflector Configurations
Model
Number
Clearance to Combustibles in (cm)
A
B
C
D
U-BEND, HORIZONTAL
VA-80
2 (5)
28 (71)
62 (157)
26 (66)
VA-115
4 (10)
34 (86
74 (188)
33 (66)
VA-150
4 (10)
37 (94)
76 (193)
36 (84)
VA-200
6 (15)
45 (114)
82 (208)
44 (112)
CLEARANCE TO COMBUSTIBLES
U-BEND, OPPOSITE 45°
Model No.
A
B
C
D
VA-80
4 (10)
50 (127)
54 (137)
18 (46)
VA-115
4 (10)
63 (160)
69 (175)
22 (56)
VA-150
4 (10)
64 (163)
71 (180)
24 (64)
VA-200
10 (25)
72 (183)
78 (198)
29 (74)
Model No.
Unvented Flue in (cm)
Vented Flue in (cm)
ABOVE
END
END
VA-80
18 (46)
26 (66)
18 (46)
VA-115
18 (46)
26 (66)
18 (46)
VA-150
18 (46)
32 (81)
18 (46)
VA-200
18 (46)
32 (81)
18 (46)
Table 2: Minimum Clearance to Combustibles (pp. 6-8)
Note: All dimensions shown are measured from outside surface of all tubes, reflectors and fittings.
Содержание VA Range
Страница 1: ...Installation Operation and Service Instructions VA RANGE MODULATING UNITARY INFRARED HEATERS ...
Страница 2: ......
Страница 43: ......