1316-900 Revision AA
10kW Precision Calorimeter
3
2
Product Overview and Specifications
Specifications
Measurement Ranges
Specification
Frequency (MHz)
50 Hz to 500 MHz
Power (W)
Connector/Frequency Dependent:
With standard HN connector
:
10 W to 10,000 W: 50 Hz to 2 MHz
10 W to 8,900 W: >2 MHz to 13.56 MHz
10 W to 6,200 W: >13.56 MHz to 27.12 MHz
10W to 5,000 W: >27.12 MHz to 40.68 MHz
10W to 4,100 W: >40.68 MHz to 60 MHZ
10 W to 2,200 W: >60 MHz to 200 MHz
10 W to 1,300 W: >200 MHz to 500 MHz
With optional 3-
1/8” connector
5
:
10 W to 10,000 W: 50 to 500 MHz
Connector Type
HN (female) standard, 3-
1/8” optional
5
Basic Accuracy
1.5 W + 0.3% Rdg
1, 2, 3, 5
Power Requirements
Calorimeter
220
–
240 VAC, 20 A
Chiller
220
–
240 VAC, 20 A
Course Chiller (optional) 208 VAC, 3-Phase, 16.5 A
6
AC Source (optional)
208 VAC, 3-Phase, 42 A
6
AC Standard (Optional)
100
–
240 VAC, 10 A
6
Physical Dimensions
(Approximate)
Specifications (continued…)