EGLOW PROBLEM SOLVING
9
Note: Main fault modes LED7
Red Cont
– Flow Switch
Red Flashing
– overheat
Green
– All ok
Check voltage input at the terminal is between 207v-
245v. Note voltage during commissioning should be
checked when the pods are acve to ensure the voltage
does not go below the minimum level.
Yes
No
Check voltage input R/H
contactor
Yes
No
Go back to source and
check wiring
Faulty wires from block to
contactor
Check ZERO voltage demand and
switch on. Contactor should
switch on
Yes
No
Check the wires from the
demand terminal to the board. If
ok replace contactor
LED 6 lit on PCB
Yes
No
Check fuse 3.15A fast
acng 20 mm
Check for 12v D.C as below
Yes
No
Replace board