POWER RATING             6kW                                 9kW                              12kW 

FLOW AND RETURN          22MM BOTTOM ENTRY    22MM BOTTOM ENTRY   22MM BOTTOM ENTRY 

ELECTRICAL SUPPLY           SP 240 VAC 50hz 30A         SP 240 VAC 50hz 40A      SP 240 VAC 50hz 50A

PROTECTION                      32 AMPS                            45 AMPS                         63 AMPS 

PUMP                                  15/50                                 15/50                              15/50 

PUMP SETTING                   AUTO                               AUTO                             AUTO 

OUTPUT TEMP  (MAX)         80°C                                 80°C                               80°C

UNDERFLOOR UNITS 

OUTPUT TEMP  (MAX)         60°C                                 60°C                               60°C 

HIGH LIMIT TEMP 
CONTROL 2 STAGE            90°/95°C                           90°/95°C                         90°/95°C 

NOM HEAT OUTPUT          20,000 BTU                       30,000 BTU                     40,000 BTU

 

AUTO AIR VENT                  FITTED                             FITTED                           FITTED

 

FLOW SWITCH                   FITTED                             FITTED                           FITTED

 

AUTO BY PASS                     FITTED                             FITTED                            FITTED

 

MIN PRESSURE COLD FILL   0.6 BAR                             0.6 BAR                          0.6 BAR

 

MAX PRESSURE HOT           3 BAR                               3 BAR                             3 BAR

 

HEAT EXCHANGERS           STAINLESS STEEL              STAINLESS STEEL            STAINLESS STEEL 

                                           3Kw PODS x 2                  3Kw PODS x 3                3Kw PODS x 4 

IPX RATING                         1                                       1                                     1

 

OPTIONAL SEALED SYSTEM KIT AA 0400

TECHNICAL SPECIFICATIONS

KIT INCLUDES:

 

COLD FILL HOUSE WITH DOUBLE ISOLATION 
3 BAR PRESSURE RELIEF VALVE 1/2” 
EXPANSION VESSEL 8 LITRES 
PRESSURE GAUGE

Содержание EG 12

Страница 1: ...INSTALLATION AND USER GUIDE 6 9 12kW ELECTRIC BOILER PLEASE RETAIN FOR REFERENCE ISSUE 2 1220...

Страница 2: ...eGlow is controlled externally with a programmer and room thermostat arrangement with voltage free switching not supplied There is a connector in the boiler casing for this purpose Standard central he...

Страница 3: ...TAGE 90 95 C 90 95 C 90 95 C NOM HEAT OUTPUT 20 000 BTU 30 000 BTU 40 000 BTU AUTO AIR VENT FITTED FITTED FITTED FLOW SWITCH FITTED FITTED FITTED AUTO BY PASS FITTED FITTED FITTED MIN PRESSURE COLD FI...

Страница 4: ...on if an indirect cylinder is to be installed Advance recommend an Advance Appliances stainless steel pre plumbed unvented cylinder and would always advise customers to consider renewable energy such...

Страница 5: ...a double pole RCD capable of breaking the full current load Remember that the full house loading must be taken into consideration when calculating mains demand Refer to IEE regulations for wiring size...

Страница 6: ...boiler controls are fully automatic The LED will turn green showing that the boiler is powered up and awaiting demand When heating demand is on set the programmer and room thermostat to call for deman...

Страница 7: ...D may flash red indicating overheat The unit is protected by the PCB controller in addition to a thermomechanical device The appliance will reset itself when it cools If the overheat recurs please ens...

Страница 8: ...8 SCHEMATIC AUTO AIR VENT HIGH LIMIT THERMOSTATS THERMISTER RETURN CONTACTOR MAINS FLOW SWITCH 3 KW PODS A RATED PUMP FLOW AUTO BYPASS CONTROL PCB...

Страница 9: ...e to ensure the voltage does not go below the minimum level Yes No Check voltage input R H contactor Yes No Go back to source and check wiring Faulty wires from block to contactor Check ZERO voltage d...

Страница 10: ...there should be con nuity Yes No Ensure system is fully purged of air If yes replace ow switch Disconnect all pods Turn on the boiler Check each of the pod leads in pairs for power note that the pods...

Страница 11: ...E IS 21 OHMS Mode SW1 SW2 SW3 SW4 Central hea ng O X X X Under oor On X X X 3KW X O O X 6KW X O On X 9KW X On O X 12KW X On On X Enable main contactor X X X On Disable main contactor X X X O Connect e...

Страница 12: ...stallation date Warranty is registered on Advance Appliances Website It is installed correctly and the benchmark paperwork is completed It is used for its intended purpose It is operated properly It h...

Отзывы: