![ADTRAN DS3-PSM Скачать руководство пользователя страница 63](http://html1.mh-extra.com/html/adtran/ds3-psm/ds3-psm_installation-and-maintenance-practice_2855151063.webp)
Menu Trees
61181041L3-5A
53
N/A
Card Type
This field displays the type of module serviced by this slot
number.
Port Tx Rate
This field displays the transmit (upstream) data rate on the
selected module.
Port Rx Rate
This field displays the receive (downstream) data rate on the
selected module.
6
Port Type
This option is used to set the Port Type to one of the
following options:
• UNI (User-to-Network Interface)
• NNI (Network-to-Network Interface)
Scrambler
This field displays whether scrambling between the PSM and
the port of the corresponding access module is enabled or
disabled.
8
Idle Cell Type
This option is used to set the Idle Cell Type to one of the
following options:
• BELLCORE (Unassigned Cell)
• ITU (Invalid Cell)
9
Maximum VCCs
This option is used to set the maximum Virtual Channel
Connections (VCCs) value to a number from 1 to 8000, or
from 1 to 4096, depending on other settings. The sum of the
current PVC, SVC, and SPVCs for this port cannot exceed
this value.
10
Maximum VPCs
This option is used to set the maximum VPCs (Virtual Path
Connections) value to a number from 1 to 256. The sum of
the current Permanent Virtual Path (PVP), SVP, SPVPs for
this port cannot exceed this value.
11
Maximum VPI Bits
This option is used to set the maximum Virtual Path
Identifier (VPI) Bits value (usually to a number from 0 to 8).
12
Maximum VCI Bits
This option is used to set the maximum Virtual Channel
Identifier (VCI) Bits value (usually to a number from 5 to 16).
13
Physical Address
This option is used to set and display the hexadecimal string
Physical Address (often the ATM address) of the selected
interface.
14
Neighbor Name
This option is used to set and display the Neighbor Name.
The Neighbor Name identifies the remote (far-end)
termination of the interface and is an alphanumeric string
up to 25 characters in length.
If the neighbor system is manageable through SNMP and
supports the object ifName, the value of this field must be
identical with that of ifName for ifEntry of the lowest level
physical interface for this port.
Table 26. ATM Provisioning Screen - Shelf # Slot # Port # Menu Options (Continued)
Option
Description
Function